Views: 222 Author: Dream Publish Time: 2025-04-22 Origin: Site
Content Menu
● Understanding the Multi Unit Abutment Screw
>> Features of Multi Unit Abutment Screws
>> Importance of the Multi Unit Abutment Screw
● When Should You Replace a Multi Unit Abutment Screw?
>> 1. Screw Loosening or Repeated Retightening
>> 2. Screw Fracture or Damage
>> 3. Stripped or Cross-Threaded Screws
>> 4. Prosthesis Instability or Patient Symptoms
>> 5. Corrosion or Contamination
● Signs Indicating the Need for Replacement
● How to Replace a Multi Unit Abutment Screw
>> Step 1: Diagnosis and Assessment
>> Step 3: Replacement Screw Selection
>> Step 4: Reinstallation and Torque Application
● Preventive Measures to Avoid Screw Replacement
>> Minimize Screw Manipulation
>> Manage Parafunctional Habits
● Advanced Considerations in Multi Unit Abutment Screw Replacement
● FAQ
>> 1. How often should a multi unit abutment screw be replaced?
>> 2. What torque values are recommended for tightening multi unit abutment screws?
>> 3. Can a fractured multi unit abutment screw be removed without damaging the implant?
>> 4. What are the risks of not replacing a failing multi unit abutment screw?
>> 5. Are replacement screws interchangeable between different implant systems?
Dental implant restorations have revolutionized prosthetic dentistry, offering patients durable and functional tooth replacements. Among the critical components in implant-supported prostheses is the multi unit abutment screw, which secures the abutment to the implant fixture. Proper maintenance and timely replacement of this screw are essential for the longevity and success of the restoration. This comprehensive article explores when and why you should replace a multi unit abutment screw, detailing signs of failure, replacement techniques, and preventive measures.
The multi unit abutment screw is a small but vital component that fastens the multi unit abutment to the dental implant. Multi unit abutments are commonly used in full-arch implant restorations and allow for screw-retained prostheses with angulation corrections. These screws are designed to withstand specific torque values, typically around 15 Ncm for angled abutments and up to 35 Ncm for straight abutments, depending on the system used.
- They have a hexagonal head or hex hole for torque application.
- Designed to fit precisely with the abutment and implant internal threads.
- Available in various lengths and designs depending on the abutment type and manufacturer.
- Require precise torque to avoid loosening or fracture.
The multi unit abutment screw is not just a mechanical fastener; it is integral to the implant-prosthesis interface's biomechanical stability. It maintains the preload that keeps the abutment tightly seated against the implant platform, preventing micro-movements that could lead to screw loosening, component wear, or bone loss around the implant. Therefore, understanding its function and maintenance is crucial for clinicians and patients alike.
Replacing a multi unit abutment screw is not a routine procedure but becomes necessary under specific circumstances:
Over time, the screw may loosen due to mechanical stresses, micro-movements, or improper torque application during placement. Repeated opening and closing of the screw can reduce its preload, increasing the risk of loosening. If the screw cannot maintain adequate torque or shows signs of loosening despite retightening, replacement is advised.
Why does loosening happen?
Screw loosening is often caused by:
- Inadequate initial torque application.
- Cyclic loading during mastication.
- Micro-gaps between the abutment and implant.
- Parafunctional habits such as bruxism.
Repeated retightening can deform the screw threads or cause wear, diminishing the screw's ability to hold proper preload.
Screws may fracture due to excessive torque, cyclic loading, or material fatigue. Fractured screws require immediate replacement to prevent damage to the implant or prosthesis. Signs of fracture include sudden instability or inability to tighten the screw fully.
Fracture risk increases if:
- The screw is overtightened beyond recommended torque.
- The screw has been reused multiple times.
- The implant or abutment threads are damaged, causing uneven stress distribution.
If the threads on the screw or abutment become stripped or cross-threaded during insertion, the screw will not secure properly. This compromises the prosthesis stability and necessitates screw replacement.
Stripping can occur due to:
- Improper alignment during insertion.
- Excessive force applied while tightening.
- Use of incompatible screws or tools.
Symptoms such as a loose or wobbly prosthesis, clicking sensations, pain when biting, swelling, or gum recession around the implant site can indicate screw failure. Persistent issues despite tightening warrant screw replacement.
These clinical signs often precede more severe complications like peri-implantitis or implant failure.
Exposure of the screw due to gum recession or poor restoration fit can lead to bacterial contamination and corrosion, weakening the screw and increasing failure risk.
Corrosion can cause:
- Loss of mechanical strength.
- Inflammation of peri-implant tissues.
- Difficulty in screw removal during maintenance.
- Loose or Wobbly Prosthesis: Micro-movements due to screw loosening.
- Persistent Pain or Sensitivity: Indicates possible screw fracture or loosening.
- Swelling or Gum Recession: Signs of peri-implant inflammation related to screw issues.
- Clicking or Floating Sensation: Often precedes complete screw failure.
- Tilted Crown or Uneven Bite: Suggests compromised screw stability.
Early detection of these signs is critical to prevent more extensive damage to the implant system.
Replacing a multi unit abutment screw involves careful clinical and laboratory steps to avoid damaging the implant or prosthesis.
- Confirm screw failure through clinical examination and radiographic imaging to check seating and integrity.
- Identify the type and manufacturer of the abutment and screw to ensure compatibility for replacement.
- Use specialized tools such as a manual torque wrench or removal drivers designed for multi unit abutments.
- In cases of fractured screws, use fragment removal instruments like the fragment fork to carefully extract broken pieces without damaging the implant.
- Select a replacement screw matching the original specifications, including length, thread design, and head dimensions.
- Prefer original manufacturer screws or verified compatible screws to ensure proper fit and function.
- Place the new screw and tighten to the recommended torque: typically 15 Ncm for angled abutments and 35 Ncm for straight abutments.
- Use a calibrated torque wrench and follow protocols such as retorquing after 10 minutes to improve screw preload and stability.
- Take a radiograph to verify the correct seating of the abutment and screw.
- Check prosthesis stability and occlusion.
Proper preventive care can significantly reduce the incidence of multi unit abutment screw failure.
Avoid overtightening which can cause screw fracture; follow manufacturer torque recommendations strictly. Under-tightening can lead to loosening, while overtightening risks fracture.
Limit the number of times the screw is removed and reinserted during clinical and lab procedures to preserve screw integrity. Repeated screw removal reduces the preload and can cause thread wear.
A well-fitting prosthesis reduces micro-movements that lead to screw loosening. Accurate impressions, precise laboratory work, and proper occlusal adjustment are critical.
Routine check-ups help detect early signs of screw loosening or damage. Early intervention can prevent more severe complications.
Address bruxism or habits that exert excessive forces on the implant restoration through occlusal guards or behavioral therapy.
Prevent peri-implantitis and inflammation that can compromise screw stability by encouraging meticulous oral hygiene.
Modern multi unit abutment screws are often made from titanium alloys or cobalt-chromium, offering high strength and corrosion resistance. However, even these materials are susceptible to fatigue over time, especially under excessive mechanical stress.
Some manufacturers have introduced screws with improved thread designs or surface treatments to enhance preload retention and reduce loosening. Clinicians should stay updated with these advancements to optimize patient outcomes.
Digital impression and CAD/CAM technology improve prosthesis fit, reducing micro-movements and screw loosening. Digital torque devices also help ensure precise screw tightening.
The multi unit abutment screw plays a crucial role in the stability and function of implant-supported prostheses. Replacement of this screw is necessary when loosening, fracture, stripping, or patient symptoms indicate failure. Proper diagnosis, careful removal, and selection of the correct replacement screw, along with adherence to torque protocols, ensure the long-term success of the restoration. Preventive strategies such as correct torque application, minimizing screw manipulation, and regular maintenance can reduce the need for screw replacement.
By understanding when and how to replace a multi unit abutment screw, clinicians can maintain the integrity of implant restorations, enhance patient comfort, and prolong the lifespan of dental implants.
A multi unit abutment screw should only be replaced when signs of failure such as loosening, fracture, or stripping occur. Routine replacement is not recommended unless clinically indicated.
Typically, angled multi unit abutment screws are tightened to 15 Ncm, while straight abutments may require up to 35 Ncm. Exceeding these values risks screw fracture.
Yes, specialized tools like fragment forks and removal drivers allow safe extraction of broken screws without implant damage when performed carefully.
Ignoring a failing screw can lead to prosthesis instability, pain, peri-implantitis, bone loss, and eventual implant failure.
No, replacement screws must match the implant platform's threadform and abutment design. Using incompatible screws can compromise fit and function, though threadform compatibility prevents implant thread damage.
[1] https://pubmed.ncbi.nlm.nih.gov/31831166/
[2] https://www.yagudentaltech.com/what-are-the-signs-of-a-failed-dental-abutment-screw.html
[3] https://pmc.ncbi.nlm.nih.gov/articles/PMC7842481/
[4] https://www.utahvalleydentallab.com/wp-content/uploads/2019/07/Multi-unit-Abutment-Placement-and-Impression-Techniques.pdf
[5] https://www.youtube.com/watch?v=rJRxl504vgU
[6] https://www.youtube.com/watch?v=Voo4hNKZ0Yc
[7] https://www.youtube.com/watch?v=TBjmI6kLbsA
[8] https://megagenamerica.com/pdf/prosth/catalog/mua.pdf
[9] https://store.nobelbiocare.com/media/eifu/IFU1020_EN_GB_02.pdf
[10] https://www.youtube.com/watch?v=bAtcvqeb53g
[11] https://www.zimvie.com/content/dam/zimvie-corporate/en/dental/literature/zv0857/zv0857_global_universal_multi-unit_abutment_brochure_final_secured.pdf
[12] https://mspace.lib.umanitoba.ca/items/8bdb7729-020f-4bda-8ade-740c9d9796b3
[13] https://burbankdental.com/multi-unit-abutments/
[14] https://www.sciencedirect.com/science/article/abs/pii/S0022391319304937
[15] https://journals.lww.com/njcp/fulltext/2021/24020/evaluation_of_the_mode_of_failure_of_abutments.12.aspx
[16] https://www.youtube.com/watch?v=rJRxl504vgU
[17] https://www.perioimplantadvisory.com/clinical-tips/periodontal-complications/article/16412213/a-solution-for-stripped-dental-implant-screws
[18] https://cortex-dental.com/product/screw-for-multi-unit-abutment/
[19] https://ticrom.com/screw/screw-multiunit/
[20] https://www.youtube.com/watch?v=YQnMviWwDrI
[21] https://gbstore.biohorizons.com/abutment-screw-pxmuas-pack-of-25
[22] https://www.eotdental.com/uploads/pdf/Multi-Unit-Abutment-Plus-Quickguide.pdf
[23] https://www.nobelbiocare.com/en-ca/technical-support-frequently-asked-questions-faqs
[24] https://www.straumann.com/content/dam/media-center/medentika/en/documents/brochure/product-information/PM01_01_0021_%20EN_Multi-unit.pdf
[25] https://support.dess-usa.com/hc/en-us/articles/9895671367316-Understanding-Multiunit-Abutment-Tops
[26] https://megagenamerica.com/pdf/prosth/catalog/mua.pdf
[27] https://usstore.biohorizons.com/abutment-screw-multi-unit-abutment
[28] https://store.nobelbiocare.com/fi/en/screw-multi-unit-abutment-angled-conical-connection-rp-wp-1
[29] https://blueskybio.com.au/store/multi-unit-abutments_1
[30] https://www.schuetz-dental.de/en/Dentist/IMPLA/Prosthetics-Cone-Connection/Hybrid-Restorations/Multi-Unit-Abutment/
[31] https://store.nobelbiocare.com/hk/en/prosthetic-screw-multi-unit-1
[32] https://www.utahvalleydentallab.com/wp-content/uploads/2019/07/Multi-unit-Abutment-Placement-and-Impression-Techniques.pdf
[33] https://js-davis.co.uk/wp-content/uploads/2023/11/Multi-Unit-Abutments-Brochure.pdf
[34] https://www.straumann.com/content/dam/media-center/medentika/en/documents/brochure/product-information/PM01_02_0030_EN_Multi-unit%20IPS_web.pdf
What Are The Common Complications From Stripped Abutment Screws?
What Is The Difference Between Titanium And Gold Straumann Abutment Screws?
Are Straumann Abutment Torque Values Different For Custom And Standard Abutments?
How Effective Is The Straumann Screw Removal Kit For Dental Implants?
Can Stainless Steel Abutment Screws Be Used In All Implant Systems?
How Do You Replace A Short Abutment Screw In Hiossen Implants?