What Tools Are Needed To Apply Torque To Astra Healing Abutments?

Views: 222     Author: Dream     Publish Time: 2025-04-25      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Content Menu

Understanding Astra Healing Abutments and Torque Importance

>> Why Torque Matters for Astra Healing Abutments

Essential Tools for Applying Torque to Astra Healing Abutments

>> 1. Torque Wrench

>> 2. Hex Screwdriver (Hand Driver)

>> 3. Slot Screwdriver

>> 4. Contra-Angle Handpiece with Torque Control

Recommended Torque Values for Astra Healing Abutments

Step-by-Step Guide to Applying Torque to Astra Healing Abutments

>> Step 1: Preparation

>> Step 2: Initial Seating

>> Step 3: Torque Application

>> Step 4: Verification

Common Issues and Troubleshooting

>> 1. Cold Welding and Difficult Removal

>> 2. Screw Stripping

>> 3. Abutment Loosening Post-Torque

Advanced Tips for Optimal Torque Application

Conclusion

FAQ

>> 1. What is the recommended torque for Astra healing abutments?

>> 2. Can I use a manual screwdriver to tighten the healing abutment?

>> 3. What happens if I over-torque the healing abutment?

>> 4. How often should the torque wrench be calibrated?

>> 5. Are there special tools for angled healing abutments?

Citations:

Applying the correct torque to Astra healing abutments is a critical step in dental implant procedures to ensure proper healing, stability, and longevity of the implant restoration. This comprehensive article explores the essential tools required for applying torque to Astra healing abutments, the recommended torque values, and best practices to avoid complications. It also includes detailed visuals and videos to enhance understanding.

astra healing abutment torque

Understanding Astra Healing Abutments and Torque Importance

Astra healing abutments are components used to protect the implant site and guide soft tissue healing after implant placement. Proper torque application ensures the abutment is securely seated without damaging the implant or surrounding tissues.

- Torque is measured in Newton-centimeters (Ncm) and applying the correct torque prevents screw loosening or fracture.

- Over-torquing can cause permanent deformation or cold welding, making removal difficult.

- Under-torquing may lead to implant instability or micro-movement, which disrupts osseointegration.

Why Torque Matters for Astra Healing Abutments

- Biomechanical Stability: Precise torque ensures the abutment-implant interface remains stable during chewing or speaking.

- Soft Tissue Preservation: Proper seating avoids pressure on gingival tissues, reducing inflammation or recession.

- Long-Term Success: Correct torque minimizes the risk of screw loosening, a common cause of implant failure.

Essential Tools for Applying Torque to Astra Healing Abutments

1. Torque Wrench

The torque wrench is the primary instrument used to apply precise torque to Astra healing abutments. It provides controlled force, ensuring the abutment is tightened to the manufacturer's recommended torque.

Types:

- Manual Torque Wrenches: Require manual force and are calibrated for specific ranges (e.g., 5–35 Ncm).

- Mechanical Torque Wrenches: Automatically stop at preset torque values, reducing human error.

- Electronic Torque Devices: Provide digital readouts and are ideal for high-precision workflows.

Recommended Torque Range for Healing Abutments:

- Healing Caps (Uni/ProHeal): 5–10 Ncm (light finger force to low torque).

- Temporary Abutments: 15 Ncm.

- Final Abutments: 20–25 Ncm.

- Restorative Driver Handle: Ergonomically designed to hold hex or slot drivers, ensuring stability during torque application.

2. Hex Screwdriver (Hand Driver)

A hex screwdriver, typically 0.5" or 1.25mm hex size, is used to initially seat the healing abutment before final torque application.

Key Features:

- Non-slip grip for controlled manual tightening.

- Compatible with most Astra implant systems.

- Limitations: Cannot deliver precise torque beyond 10 Ncm, necessitating a torque wrench for final adjustments.

3. Slot Screwdriver

For angled healing caps or bridge screws, a slot screwdriver is used to secure components before torque wrench application.

- Angled Abutments: These require a slot driver to access screws positioned at non-vertical angles.

- Material: Stainless steel tips prevent wear during repeated use.

4. Contra-Angle Handpiece with Torque Control

Some clinicians use a contra-angle handpiece preset at low rpm (e.g., 25 rpm) with a torque control setting to apply torque gently and consistently.

Advantages:

- Reduces hand fatigue during multiple implant placements.

- Ensures uniform torque across all abutments.

- Calibration: Regular calibration is critical to maintain accuracy.

astra healing abutment sizes

Recommended Torque Values for Astra Healing Abutments

Component Recommended Torque (Ncm) Tool Used Clinical Purpose
Healing Abutment Uni 5–10 Ncm Manual Hex Screwdriver or Torque Wrench Soft tissue contouring
ProHeal Cap 5–10 Ncm Hex Screwdriver or Torque Wrench Immediate temporization
Healing Cap Angled 5–10 Ncm Slot Screwdriver or Torque Wrench Angled implant access
Temporary Abutments 15 Ncm Torque Wrench Provisional restorations
Final Uni Abutment 15 Ncm Torque Wrench Long-term crown support
Angled Abutment Screw 20–25 Ncm Hex Screwdriver or Torque Wrench Fixed bridge frameworks

Step-by-Step Guide to Applying Torque to Astra Healing Abutments

Step 1: Preparation

- Sterilization: Autoclave all tools, including the torque wrench and drivers, to prevent infection.

- Abutment Selection: Use the Abutment Depth Gauge to confirm the healing abutment height matches the gingival thickness.

- Patient Assessment: Ensure the implant site is free of inflammation or debris before placement.

Step 2: Initial Seating

- Manual Placement: Insert the healing abutment into the implant by hand.

- Hex Driver Use: Secure the abutment with a hex screwdriver using light finger force (5–10 Ncm). Avoid excessive pressure.

Step 3: Torque Application

- Tool Setup: Attach the hex driver to the restorative driver handle and connect it to the torque wrench.

- Positioning: Align the torque wrench perpendicular to the implant axis to avoid angled force.

- Torque Delivery: Pull the torque wrench arm smoothly in the direction of the arrow until the preset torque is achieved.

Step 4: Verification

- Tactile Check: Gently test the abutment for movement. If loose, re-torque within the recommended range.

- Radiographic Confirmation: Take a periapical X-ray to verify proper seating and alignment.

Common Issues and Troubleshooting

1. Cold Welding and Difficult Removal

- Cause: Over-torquing (>30 Ncm) generates heat, fusing the abutment screw to the implant.

- Solutions:

- Apply ice to contract the metal.

- Use ultrasonic vibration to break the bond.

- Utilize a screw removal kit (e.g., Komet Dental).

2. Screw Stripping

- Prevention: Always use the correct hex size (1.25mm for most Astra systems).

- Repair: Convert the stripped hex into a slot with a round bur, then use a slotted screwdriver.

3. Abutment Loosening Post-Torque

- Causes: Insufficient torque, poor implant positioning, or occlusal overload.

- Resolution: Re-torque to the recommended value and evaluate the occlusion.

Advanced Tips for Optimal Torque Application

- Lubrication: Apply a small amount of petroleum jelly to the screw threads to reduce friction.

- Sequential Torque: For multi-unit restorations, tighten abutments in a cross pattern to distribute force evenly.

- Post-Torque Monitoring: Schedule follow-ups at 2–4 weeks to check stability, especially for immediate-load implants.

Conclusion

Applying the correct torque to Astra healing abutments is essential for implant success and patient comfort. The key tools include a calibrated torque wrench, hex screwdriver, and occasionally a slot screwdriver for angled components. Following manufacturer torque recommendations—typically 5–10 Ncm for healing abutments—ensures secure seating without risking damage or difficult removal. Proper technique, combined with the right instruments, leads to optimal healing and implant stability. Regular tool maintenance and adherence to best practices minimize complications, ensuring predictable outcomes in both simple and complex cases.

astra ev uni healing abutment

FAQ

1. What is the recommended torque for Astra healing abutments?

The recommended torque for Astra healing abutments is generally 5–10 Ncm using light finger force or a torque wrench, depending on the specific healing cap type.

2. Can I use a manual screwdriver to tighten the healing abutment?

Yes, a manual hex screwdriver can be used for initial seating with light finger force, but final torque should be applied with a torque wrench for accuracy.

3. What happens if I over-torque the healing abutment?

Over-torquing can cause cold welding, making the abutment difficult to remove and potentially damaging the implant or screw threads.

4. How often should the torque wrench be calibrated?

Torque wrenches should be periodically calibrated according to manufacturer instructions to ensure accurate torque delivery and avoid excessive force.

5. Are there special tools for angled healing abutments?

Yes, angled healing abutments may require a slot screwdriver in addition to the hex driver and torque wrench to properly seat and torque the components.

Citations:

[1] https://www.dentsplysirona.com/content/dam/master/education/documents/upload/1/1235869%20Screw_retained%20restorations.pdf.coredownload.pdf

[2] https://nuartdental.com/wp-content/uploads/2020/09/astra-torque-guide.pdf

[3] https://edisonmed.com/healing-abutment-cap-sp-ssp-astra-techr-conical-conn-tx-osseospeedtm-3-5-4-0-rp

[4] https://www.youtube.com/watch?v=AwxH1w_PpVI

[5] https://www.youtube.com/watch?v=-jUPqZkjklM

[6] https://www.dentsplysirona.com/content/dam/master/education/documents/upload/A/ATIS%20EV_Attachment_retained%20restorations%20manual_32671184-US-1703.pdf

[7] https://www.dentsplysirona.com/content/dam/master/education/documents/upload/1/1235869%20Screw_retained%20restorations.pdf

[8] https://www.dentaltown.com/Images/Dentaltown/magimages/0419/DT0419_MB4_AG.pdf

[9] https://adldental.com/wp-content/uploads/2018/10/ADL_Torque-Spec-Sheet3.pdf

[10] https://edisonmed.com/healing-abutment-cap-astra-techr-conical-conn-tx-osseospeedtm-4-5-5-0-wp

[11] https://www.spotimplant.com/en/knowledge-base/abutment-screw-torque-and-driver/

[12] https://www.mavraidopoulos.gr/AttachmentRetainedRestorationsASTRATECHImplantSystemEV.pdf

[13] http://removpros.dentistry.dal.ca/ewExternalFiles/Astra%20Torque%20Guide.pdf

[14] https://www.burdettedental.com/wp-content/uploads/2016/11/7204-Torque-Spec-Sheet.V5.web_.pdf

[15] https://www.youtube.com/watch?v=GTmETAndrVo

[16] https://www.dentsplysirona.com/en-us/shop/BP-1000191337/astra-tech-implant-system-ev-torque-wrench-ev.html

[17] https://assets.dentsplysirona.com/dentsply/pim/manufacturer/Implants/Implant_systems/Astra_Tech_Implant_System/Prosthetics/32671193-USX-1702%20Cement%20retained%20restorations_LR.pdf

[18] https://helmdentallaboratory.com/tpn/c/C1050/docs/20220512-HDL-Abutment-torque-4-22-FINAL.pdf

[19] https://dpsdental.com/wp-content/uploads/2022/04/Implant-Torque-Guide-2022.pdf

[20] https://carltondentallabs.com/wp-content/uploads/2020/09/torque-specs.pdf

[21] https://www.dentsplysirona.com/content/dam/flagship/en/explore/implantology/implant-systems/astra-tech-implant-system-ev/documents/documents/IMP-Product%20catalog%20Astra%20Tech%20Implant%20System%20EV_32671941-USX-2003.pdf

[22] https://www.dentsplysirona.com/en-us/shop/I-BP-1000191165/astra-tech-implant-system-tx-healing-abutments.html

[23] https://www.dentsplysirona.com/en-us/shop/product-page.html/I-BP-1000191166/astra-tech-implant-system-tx-healing-abutment-profile.html

[24] https://www.kleinsmiede-vanamerongen.nl/Kleinsmiede-vanamerongen/Implantaten_files/Astra.pdf

[25] https://www.dentsplysirona.com/content/dam/master/education/documents/upload/1/1235869%20Screw_retained%20restorations.pdf.coredownload.pdf

[26] https://www.dentsplysirona.com/content/dam/master/product-procedure-brand-categories/implant-dentistry/product-categories/cover-screws---healing-abutments/healing-abutments/ifu/5687/IMP-US-IFU-Astra-Tech-Implant-System-Healing-abutments-EN-US-5687-2023-12.pdf

[27] https://assets.dentsplysirona.com/dentsply/pim/manufacturer/Implants/Implant_systems/Astra_Tech_Implant_System/Instruments/Repair__retrieval/32671187-USX-1711%20Repair%20procedures%20Manual%20and%20Product%20catalog%20Astra%20Tech%20Implant%20System_LR.pdf

[28] https://www.dentsplysirona.com/content/dam/master/education/documents/upload/A/ATIS%20EV%20Screw-retained%20manual%20_32671183-US-1705.pdf

[29] https://www.osseonews.com/astra-implant-rotated-after-retorquing-questionable-prognosis/

[30] https://www.dentaltown.com/Images/Dentaltown/magimages/0419/DT0419_MB4_AG.pdf

[31] https://store.nobelbiocare.com/ca/en/multi-unit-abutment-3-5mm-astra-tech-osseospeedr-wp-1

[32] https://www.youtube.com/watch?v=u1WGmF4QwYI

[33] https://www.dentsplysirona.com/content/dam/master/education/documents/upload/A/ATIS%20EV_Attachment_retained%20restorations%20manual_32671184-US-1703.pdf

[34] https://www.osseonews.com/astra-tech-implants-anyone-else-experience-flowering-at-the-top-of-the-implants/

CONTACT US

Shenzhen Yagu Dental Technology Co.,Ltd
  Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096
  Yagutech@hotmail.com
  8613631613096
 +8613631613096
Home
Copyright © Shenzhen Yagu Dental Technology Co.,Ltd
 Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096
  Yagutech@hotmail.com