● Step-by-Step Procedure for Applying NobelReplace Abutment Screw Torque
>> Step 1: Hand-Tighten the Abutment Screw
>> Step 2: Attach the Implant Driver to the Torque Wrench
>> Step 3: Set the Torque Wrench
>> Step 4: Apply the Final Torque
>> Step 5: Verify Seating with Radiographs
● Best Practices and Tips for NobelReplace Abutment Screw Torque
● Frequently Asked Questions (FAQ)
>> 1. What is the recommended torque for NobelReplace abutment screws?
>> 2. Can I use a hand screwdriver instead of a torque wrench?
>> 3. How often should I calibrate my torque wrench?
>> 4. What happens if I overtighten the abutment screw?
>> 5. Is retorquing the abutment screw necessary?
Dental implantology demands precision and the correct application of torque to ensure the longevity and stability of implant restorations. Among the various implant systems, NobelReplace is a widely used platform that requires specific tools and protocols to achieve the recommended abutment screw torque. This article delves deeply into the tools needed for NobelReplace abutment screw torque, how to use them properly, and best practices to avoid complications such as screw loosening or fracture. We will also include visual aids and videos to enhance understanding.
The abutment screw torque is the force applied to secure the abutment to the implant fixture. For NobelReplace implants, the recommended torque is typically 35 Ncm (Newton centimeters), although this can vary slightly depending on the abutment type and implant diameter. Applying the correct torque is critical because:
- It ensures a stable joint between the implant and abutment.
- It prevents screw loosening, which is a common cause of implant restoration failure.
- It avoids overtightening, which can lead to screw fracture or damage to the implant components.
Torque is a measure of rotational force, and in implant dentistry, it directly influences the preload on the abutment screw. Preload is the tension created in the screw when tightened, which clamps the abutment and implant together. Correct preload prevents micromovements at the implant-abutment interface, which can cause mechanical complications or bacterial infiltration.
For NobelReplace implants, the 35 Ncm torque corresponds to an optimal preload that balances mechanical stability and component longevity. Applying less torque may result in insufficient preload, risking screw loosening, while excessive torque can overstress the screw, causing deformation or fracture.
Achieving the correct torque requires specialized tools designed for the NobelReplace system. Using the wrong tools can compromise the implant-abutment connection and patient outcomes.
A torque wrench is the primary tool used to apply the precise torque to the abutment screw. For NobelReplace systems, the Manual Torque Wrench Prosthetic is commonly used. It features a ratchet mechanism and a spring arm design for consistent torque application.
- Manual Torque Wrench Prosthetic: This wrench allows the clinician to apply torque up to the recommended 35 Ncm safely.
- Calibration: It is crucial to regularly calibrate the torque wrench to ensure accuracy, as repeated sterilization and use can affect its performance.
- Directional Arrow: The wrench has an arrow indicating the tightening direction (clockwise). The arrow must face the user during tightening to ensure proper torque application.
There are also mechanical and electronic torque wrenches available, which provide digital readouts and more precise control. However, the manual wrench remains the standard in many clinical settings due to its reliability and ease of sterilization.
NobelReplace implants use a tri-channel internal connection requiring specific drivers:
- Unigrip Implant Driver: Designed to fit the tri-channel connection, it ensures a secure fit to avoid slipping during torque application.
- Torque Wrench Adapter: Connects the implant driver to the torque wrench. It has a locking mechanism (click-fit) to prevent disengagement during tightening.
The implant driver must be compatible with the specific NobelReplace implant size and connection type to ensure proper engagement. Using non-compatible drivers risks damaging the internal connection or stripping the screw head.
Before using the torque wrench, the abutment screw is initially hand-tightened using a Screwdriver Unigrip or similar manual driver. This step ensures the screw is seated correctly before applying the final torque.
Hand tightening helps align the threads and prevents cross-threading, which can damage the implant or screw. It also allows the clinician to feel any resistance or misfit before applying full torque.
After tightening, radiographic verification is recommended to confirm the correct seating of the abutment and screw. This helps detect any misalignment or incomplete seating that could compromise the joint.
Common imaging methods include periapical X-rays or cone-beam computed tomography (CBCT), which provide detailed views of the implant-abutment interface.
Maintaining the torque wrench and drivers is essential for consistent performance. Sterilization must follow manufacturer guidelines to avoid corrosion or mechanical wear. Some torque wrenches require disassembly for cleaning, while others are autoclavable as-is.
- Use the Unigrip screwdriver to hand-tighten the abutment screw.
- Ensure the screw is fully seated but do not apply excessive force.
- This initial tightening aligns the screw threads and prevents cross-threading.
- Insert the appropriate implant driver into the torque wrench adapter.
- Connect the adapter to the torque wrench until a click confirms proper engagement.
- Confirm the driver fits snugly without wobble to ensure accurate torque transfer.
- Confirm the directional arrow is facing you (clockwise tightening).
- Adjust the torque wrench to the recommended torque setting (usually 35 Ncm for NobelReplace abutments).
- Double-check the torque setting before proceeding.
- Place the torque wrench over the implant driver.
- Apply steady pressure until the wrench clicks or ratchets, indicating the preset torque has been reached.
- Avoid exceeding the recommended torque to prevent screw fracture.
- If the wrench does not click, stop and reassess the setup.
- Take a radiograph to verify the abutment is fully seated.
- Check for any gaps or misalignment.
- If any discrepancies are noted, loosen and retighten following the protocol.
- Some clinicians recommend retorquing after 10-15 minutes to compensate for screw settling.
- Repeat the torque application gently without exceeding the preset torque.
- Use Only Original Nobel Biocare Components: Compatible parts may not have the same thread pitch or material properties, risking screw loosening or damage.
- Avoid Lubricants or Ointments: These can affect torque and screw retention, especially under vibration.
- Limit Screw Reuse: Repeated tightening and loosening reduce the screw's ability to maintain torque. Replace screws after about five uses.
- Regularly Calibrate Torque Wrenches: To maintain accuracy and avoid over- or under-torquing.
- Retorque Protocol: Some studies suggest retorquing the abutment screw after a short interval (e.g., 10 minutes) can improve preload and reduce loosening risk.
- Clean Threads Before Assembly: Ensure both implant and abutment screw threads are free from debris or contaminants to achieve optimal torque.
- Store Tools Properly: Protect torque wrenches and drivers from damage by storing them in dedicated cases.
- Training and Familiarization: Clinicians should undergo training on NobelReplace torque protocols to minimize errors and improve outcomes.
- Document Torque Application: Recording torque values and procedures in patient records supports quality control and legal documentation.
Achieving the correct NobelReplace abutment screw torque is essential for the stability and longevity of implant-supported restorations. The key tools required include a calibrated manual torque wrench, specific implant drivers, and torque wrench adapters designed for the NobelReplace system. Proper technique involves hand-tightening followed by precise torque application, with radiographic verification to ensure correct seating. Adhering to manufacturer guidelines, using original components, and maintaining torque tools are critical to preventing complications such as screw loosening or fracture. Incorporating retorquing protocols further enhances the reliability of the implant-abutment connection. By following these protocols and using the right tools, clinicians can optimize clinical outcomes for their patients.
The recommended torque is generally 35 Ncm for most NobelReplace abutments, but always refer to the specific abutment instructions for exact values.
No. Hand screwdrivers cannot reliably apply the correct torque, risking under-tightening or overtightening. A calibrated torque wrench is mandatory for precision.
Calibration should be performed at least annually or more frequently if the wrench is heavily used or sterilized often to ensure accurate torque delivery.
Overtightening can cause screw fracture or damage to implant components, leading to restoration failure and potential clinical complications.
Retorquing after an initial tightening (e.g., after 10 minutes) can help compensate for the settling effect and improve screw preload, reducing the risk of loosening.
[1] https://www.nobelbiocare.com/es-es/system/files/gmt_import/N1%20Manual-%20Final%20Restorations_GMT79631.pdf
[2] https://edeldental.hu/images/pdf/nobelreplace_tapered_sales_brochure_en.pdf
[3] https://www.youtube.com/watch?v=x_SNgKu3Clw
[4] https://www.bioclinicalservices.com.au/nobel-biocare/surgical/manual-torque-wrenches-surgical-and-prosthetic-instructions-for-use
[5] https://www.straumann.com/content/dam/media-center/medentika/en/documents/brochure/product-information/PM02_01_0044_EN_F-Serie_print.pdf
[6] https://blog.iti.org/clinical-insights/angulated-screw-channel-solutions-in-implant-dentistry/
[7] https://www.youtube.com/watch?v=leUA1mqve8c
[8] https://pmc.ncbi.nlm.nih.gov/articles/PMC5394346/
[9] https://mspace.lib.umanitoba.ca/bitstream/handle/1993/36571/Max_Li.pdf
[10] https://www.nobelbiocare.com/en-int/blog/productivity/4-rules-for-using-torque-drivers-and-implant-screws
[11] https://www.spotimplant.com/en/knowledge-base/abutment-screw-torque-and-driver/
[12] https://www.eotdental.com/uploads/pdf/NobelParallel-Manual%20.pdf
[13] https://www.burdettedental.com/wp-content/uploads/2016/11/7204-Torque-Spec-Sheet.V5.web_.pdf
[14] https://www.nobelbiocare.com/sites/g/files/wdvifx201/files/Prosthetic%20Torque%20Guide.pdf
[15] https://www.straumann.com/content/dam/media-center/medentika/en/documents/brochure/product-information/PM02_01_0044_EN_F-Serie_print.pdf
[16] https://gkydentalarts.com/assets/resources/Torque-Spec-Sheet.pdf
[17] https://store.nobelbiocare.com/us/en/screw-ceramic-abutment-nobelreplace-np
[18] https://www.youtube.com/watch?v=rJRxl504vgU
[19] https://dentallabnetwork.com/forums/threads/nobel-replace-loosening.7420/
[20] https://www.eotdental.com/uploads/pdf/NobelParallel-Manual%20.pdf
[21] https://triaddentalstudio.com/wp-content/uploads/2019/09/Updated_Implant-Abutment-Torque-Settings-Resized-to-Letter.pdf
[22] https://store.nobelbiocare.com/be/en/abutment-screw-nobelreplace-np-1
[23] https://www.youtube.com/watch?v=LtvwS0HuUBg
[24] https://shop.straumann.com/medentika/di/en_di/MPS/Nobel-Biocare--compatible/F-Series---compatible-with-Nobel-Biocare-NobelActive%C2%AE-NobelReplace%C2%AE-Conical/F-Serie-Abutment-screw/p/F%2068/
[25] https://shop.straumann.com/medentika/di/en_di/MPS/Nobel-Biocare--compatible/F-Series---compatible-with-Nobel-Biocare-NobelActive%C2%AE-NobelReplace%C2%AE-Conical/F-Serie-Abutment-screw/p/F%20600/
[26] https://www.nobelbiocare.com/en-int/top-questions-frequently-asked-questions-faqs
[27] https://www.nobelbiocare.com/en-int/technical-support-frequently-asked-questions-faqs
[28] https://www.burdettedental.com/wp-content/uploads/2016/11/7204-Torque-Spec-Sheet.V5.web_.pdf
[29] https://adldental.com/wp-content/uploads/2018/10/ADL_Torque-Spec-Sheet3.pdf
[30] https://msa.sm.ee/ctrl/et/Fail/laadi_alla/138535
[31] https://pmc.ncbi.nlm.nih.gov/articles/PMC10051685/
[32] https://selserdental.com/wp-content/uploads/2017/11/Torque-Spec-Sheet.pdf
[33] https://www.wiandlab.com/many-times-can-torque-screw-implant/
[34] https://www.nobelbiocare.com/es-es/system/files/gmt_import/N1%20Manual-%20Final%20Restorations_GMT79631.pdf
[35] https://puget-sound-perio.squarespace.com/s/Torque-Guide.pdf
[36] https://www.wiandlab.com/wp-content/uploads/2022/12/Wiand-Import-Torque-Spec-Guide-1.pdf
What Are The Common Complications From Stripped Abutment Screws?
What Is The Difference Between Titanium And Gold Straumann Abutment Screws?
Are Straumann Abutment Torque Values Different For Custom And Standard Abutments?
How Effective Is The Straumann Screw Removal Kit For Dental Implants?
Can Stainless Steel Abutment Screws Be Used In All Implant Systems?
How Do You Replace A Short Abutment Screw In Hiossen Implants?