Views: 222 Author: Dream Publish Time: 2025-04-15 Origin: Site
Content Menu
● Understanding the Role of Abutment Screws in Implant Dentistry
● Key Features of Hiossen Abutment Screws
>> Precision Engineering and Material Quality
>> Advanced Design for Secure Fit
>> Recommended Torque Specifications
>> Compatibility with Various Abutment Types
>> Enhanced Durability with EK System
● Clinical Advantages of Hiossen Abutment Screws
>> Minimizing Screw Loosening and Fracture
>> Facilitating Easy Screw Removal
>> Supporting Fast Prosthetic Loading
>> Promoting Long-Term Implant Success
● Troubleshooting Common Issues with Abutment Screws
● Best Practices for Using Hiossen Abutment Screws
● Innovations and Future Directions in Hiossen Abutment Screws
● FAQ
>> 1. What materials are Hiossen abutment screws made of?
>> 2. How does the Hiossen E-driver improve abutment screw placement?
>> 3. What torque should be applied when tightening Hiossen abutment screws?
>> 4. Can Hiossen abutment screws be used with different types of abutments?
>> 5. What should be done if an abutment screw fractures?
Dental implantology has revolutionized restorative dentistry, offering patients durable and natural-looking solutions for missing teeth. Among the critical components ensuring the success and longevity of dental implants are abutment screws. Hiossen abutment screws have gained recognition for their reliability and performance in implant dentistry. This comprehensive article explores what makes Hiossen abutment screws a trusted choice for dental professionals and patients alike.
Before delving into the specifics of Hiossen abutment screws, it is essential to understand their function. An abutment screw connects the abutment—the part that supports the prosthetic tooth—to the dental implant embedded in the jawbone. This connection must be secure to withstand the forces of chewing and prevent complications such as screw loosening or fracture.
The abutment screw plays a pivotal role in maintaining the integrity of the implant-prosthesis interface. If the screw fails, it can lead to prosthetic instability, patient discomfort, and the need for additional corrective procedures. Therefore, the choice of abutment screw is critical for the long-term success of implant restorations.
Hiossen abutment screws are manufactured with high precision using medical-grade titanium alloys, known for their biocompatibility and strength. Titanium is the gold standard in implant dentistry due to its excellent osseointegration properties and resistance to corrosion in the oral environment.
The use of titanium alloys in Hiossen abutment screws ensures that the screws can endure the mechanical stresses of mastication without deforming or breaking. Additionally, the biocompatible nature of titanium minimizes the risk of inflammatory reactions in the surrounding soft tissues, promoting healthy peri-implant conditions.
One of the standout features of Hiossen abutment screws is their unique design incorporating three latching slots. These slots allow the abutment to firmly attach to the implant before the screw is engaged, creating a stable and precise connection.
This design reduces micro-movements at the implant-abutment interface, which are often responsible for screw loosening and mechanical complications. By minimizing these micro-movements, Hiossen abutment screws contribute to the overall stability and longevity of the implant restoration.
Proper torque application is essential for the success of any implant restoration. Hiossen provides clear guidelines for tightening torque, typically recommending 30 Ncm for abutment screws. This torque value is carefully calibrated to ensure the screw is tight enough to prevent loosening but not so tight as to risk fracture.
To assist clinicians in achieving the correct torque, Hiossen offers the proprietary E-driver tool. This tool is designed to deliver precise torque control, improving clinical efficiency and reducing the risk of human error during screw placement.
Hiossen abutment screws are compatible with a wide range of abutments, including cement-retained, screw-retained, and combination prostheses. This versatility allows clinicians to tailor the prosthetic solution to the patient's specific needs without compromising the reliability of the screw connection.
Whether the restoration requires a custom abutment or a stock abutment, Hiossen abutment screws provide a dependable interface that supports optimal prosthetic function.
The EK implant system by Hiossen features a 44% thicker implant wall and a 50% increase in abutment connection surface area compared to conventional systems. These enhancements contribute to greater durability and resistance to mechanical stress.
The abutment screw in the EK system is designed to withstand higher loads, making it particularly suitable for patients with high occlusal forces or for use in posterior regions where chewing forces are greatest. This robustness helps prevent mechanical complications and supports long-term implant success.
Screw loosening is one of the most common complications in implant dentistry, often leading to prosthetic instability and patient discomfort. Hiossen abutment screws, combined with their E-driver tool, minimize the risk of loosening by ensuring precise torque application and secure seating of the abutment.
The three latching slots design also plays a crucial role in reducing micro-movements that can cause screw loosening. Clinical studies have shown that implants using Hiossen abutment screws exhibit lower rates of screw loosening compared to other systems.
In rare cases where screw fracture occurs, Hiossen offers an Easy Screw Removal (ESR) kit that allows clinicians to safely and efficiently remove fractured screws without damaging the implant or surrounding bone.
The ESR kit includes specialized tools designed to engage and extract broken screw fragments, preserving the integrity of the implant fixture. This feature is invaluable in complex clinical situations, reducing treatment time and improving patient outcomes.
Thanks to the advanced surface technology and design of Hiossen implants and abutment screws, clinicians can often proceed with faster prosthetic loading protocols. This means patients can receive their final restorations sooner, improving satisfaction and reducing overall treatment time.
The enhanced stability provided by Hiossen abutment screws supports immediate or early loading protocols, which are increasingly preferred in modern implant dentistry for their efficiency and patient comfort.
Hiossen implants and abutment screws have demonstrated high success rates in clinical studies worldwide. Their precise fit, material quality, and design contribute to long-lasting implant stability and function, reducing the need for revision procedures.
Long-term follow-up studies indicate that implants using Hiossen abutment screws maintain excellent osseointegration and prosthetic stability over many years, making them a reliable choice for both clinicians and patients.
Despite the reliability of Hiossen abutment screws, some clinical challenges may arise, such as repeated screw loosening. Factors contributing to this include implant angulation, occlusal forces, and prosthetic design.
Improper implant angulation can place uneven stress on the abutment screw, increasing the risk of loosening or fracture. In such cases, using angled abutments or custom abutments designed to correct angulation can help distribute forces more evenly.
Excessive occlusal forces, especially in patients with parafunctional habits like bruxism, can overload the abutment screw. Occlusal adjustments, night guards, or selecting implants and screws designed for higher load tolerance (such as the Hiossen EK system) can mitigate these risks.
Poor prosthetic design, such as inadequate support or improper fit, can contribute to screw complications. Ensuring precise prosthetic fabrication and proper occlusal contacts is essential for maintaining screw stability.
- Follow Torque Recommendations: Always use the recommended 30 Ncm torque with the Hiossen E-driver to ensure optimal screw tightness.
- Use Compatible Components: Ensure that abutments and screws are from the same system to maintain compatibility and fit.
- Regular Maintenance: Schedule periodic check-ups to monitor screw stability and prosthetic integrity.
- Patient Education: Inform patients about avoiding excessive forces on implants, especially during the healing phase.
Hiossen continues to invest in research and development to improve the performance of their abutment screws. Innovations such as surface treatments to enhance screw-implant interface friction, and the development of new alloys with improved fatigue resistance, are on the horizon.
Additionally, digital dentistry integration is becoming more prominent. Hiossen is working on abutment screws and implant components compatible with digital workflows, including CAD/CAM custom abutments and guided surgery kits, which further improve precision and clinical outcomes.
Hiossen abutment screws stand out in implant dentistry due to their precision engineering, high-quality materials, and innovative design features such as the three latching slots and compatibility with the EK system. Their recommended torque specifications and specialized tools like the E-driver ensure secure and reliable abutment fixation, minimizing complications like screw loosening and fracture.
Additionally, Hiossen's support with removal kits and versatile abutment options enhances clinical outcomes and patient satisfaction. Overall, Hiossen abutment screws provide a dependable foundation for successful implant restorations, contributing to long-term oral health and function.
By integrating advanced design, material excellence, and clinical support tools, Hiossen abutment screws empower dental professionals to deliver predictable, durable, and patient-friendly implant solutions.
Hiossen abutment screws are made from medical-grade titanium alloys, which offer excellent biocompatibility, corrosion resistance, and mechanical strength suitable for long-term implant stability.
The E-driver provides precise torque control, reducing the risk of screw fracture or loosening. Its contra-angle design also facilitates easier access in posterior regions, shortening chair time during procedures.
Hiossen recommends a tightening torque of 30 Ncm for regular abutment screws, which balances secure fixation without risking screw damage.
Yes, Hiossen abutment screws are compatible with cement-retained, screw-retained, and combination prosthetic abutments, offering flexibility in restorative options.
Hiossen provides an Easy Screw Removal (ESR) kit designed to safely extract fractured screws without damaging the implant or surrounding bone, facilitating efficient clinical management.
[1] https://hiossen.com/wp-content/uploads/2024/01/Hiossen-Implant-System_PC24HISLTR1.0.pdf
[2] https://hiossen.com/products/e-driver/
[3] https://hiossen.com/wp-content/uploads/2022/05/Product-Catalog_2022.pdf
[4] https://www.youtube.com/watch?v=bzdSGcxdmt8
[5] https://www.dentmax.com.tr/en/treatments/hiossen-dental-mplant-stanbul-turkey
[6] https://dentallabnetwork.com/forums/threads/screw-coming-loose-repeatedly-whats-wrong.31924/
[7] https://fineupclinic.com/blog/hiossen-vs-osstem-implant-comparison-2024-which-one-to-choose/
[8] https://www.youtube.com/watch?v=zTxhDmPZjAM
[9] https://hiossen.com/hiossen-blog/how-long-should-implants-last/
[10] https://hiossen.com/products/ek-implant-system/
[11] https://www.hiossenimplantcanada.ca/abutments/
[12] https://uniqa.dental/product/screw-for-abutment-for-hiossen-conical-connection-et-system-rp/
[13] https://hiossen.com/products/stock-abutments/
[14] https://hiossen.com/hiossen-blog/cement-vs-screw-retained-implant-crowns/
[15] https://www.dentmax.com.tr/en/treatments/hiossen-dental-mplant-stanbul-turkey
[16] https://www.osstem.com.hk/wp-content/uploads/2021/08/Hiossen-Catalog_2021-edited-23-Apr-2021-e-version.pdf
[17] https://dentallabnetwork.com/forums/threads/hoissen-anyone.10652/
[18] https://hiossen.com
[19] https://www.osseonews.com/hiossen-dental-implants-open-discussion/
[20] https://glidewelldirect.com/products/multi-unit-abutment-angled-screw-hiossen-hg-standard
[21] https://glidewelldirect.com/products/multi-unit-abutment-angled-screw-hiossen-hg-mini
[22] https://eshop.hiossen.com/prosthetics/ek-et-system/healing-abutment-cover-screw/
[23] https://shop.straumann.com/medentika/se/en_se/MPS/HiOssen-Implant--compatible/c/cat_med_hiossen
[24] https://shop.straumann.com/medentika/us/en_us/MPS/HiOssen-Implant--compatible/c/cat_med_hiossen
[25] https://32dentalab.com/products/regular-platform-abutment-screw-osstem%C2%AE-ts-hiossen%C2%AE-et-compatible
[26] https://www.zestdent.com/locator-hiossen-et-iii-sa-fixture-s-abutment
[27] https://www.instagram.com/hiossen/
[28] https://hiossen.com/wp-content/uploads/2022/05/ET-III-IV-System_PB22ETSLTR1.0_Pages.pdf
[29] https://www.instagram.com/hiossenimplant.canada/
[30] https://www.youtube.com/c/HiossenImplants/videos
[31] https://www.hiossenimplantcanada.ca/k3-chair-photo-collection/
[32] https://www.youtube.com/@HiossenImplants
[33] https://www.instagram.com/hiossenimplant.canada/reel/DICVmqTg8-Y/
[34] https://hiossen.com/wp-content/uploads/2024/08/Rescue-Kits-Manual_PM23RCKLTR1.0-1.pdf
[35] https://www.hiossenimplantcanada.ca/tag/abutment-screw/
[36] https://hiossen.com/hiossen-blog/what-are-the-parts-of-a-dental-implant/
[37] https://eshop.hiossen.com
[38] https://hiossen.com/hiossen-blog/common-questions-about-dental-implants/
[39] https://hiossen.com/dental-implants/guide-to-dental-implants/
[40] https://www.hiossenimplantcanada.ca/the-effect-of-internal-implant-abutment/
[41] https://hiossen.com/dental-implants/starting-dental-implant-practice/
[42] https://www.spotimplant.com/en/knowledge-base/abutment-screw-torque-and-driver/
[43] https://uniqa.dental/product/screw-for-abutment-for-hiossen-conical-connection-et-system-rp/?add-to-cart=11312
[44] https://www.yelp.com/biz/hiossen-tempe-3
[45] https://www.osstemuk.co.uk/DOCUMENTS/IMPLANTS/ETNH/DOWNLOADS/ETNH-Brochure.pdf
[46] https://www.ddsgadget.com/hiossen-compatible-multi-unit-straight-abutment.html
[47] https://hiossen.com/wp-content/uploads/2024/07/EK-Brochure_PB23EKSLTR1.0.pdf
[48] https://www.reddit.com/r/Dentistry/comments/xw5jyn/opinions_about_an_implant_brand/
[49] https://hiossen.com/products/t2-cbct/
[50] https://www.youtube.com/watch?v=vpp2PgRBbok
[51] https://hiossen.com/products/e-driver/
[52] https://www.linkedin.com/pulse/case-study-3i-hiossen-abutment-screw-retrieval-charles-mastrovich
[53] https://www.dentmax.com.tr/tedaviler/hiossen-dental-implant
What Are The Common Complications From Stripped Abutment Screws?
What Is The Difference Between Titanium And Gold Straumann Abutment Screws?
Are Straumann Abutment Torque Values Different For Custom And Standard Abutments?
How Effective Is The Straumann Screw Removal Kit For Dental Implants?
Can Stainless Steel Abutment Screws Be Used In All Implant Systems?
How Do You Replace A Short Abutment Screw In Hiossen Implants?