Introduction to Astra Tech Abutment Screws

>> Recommended Torque Values

Consequences of Incorrect Torque

>> Too High Torque

>> Too Low Torque

Importance of Proper Torque

>> Torque Wrenches for Astra Tech Implants

Clinical Considerations

>> Material Considerations

>> Abutment Design

Preload and Screw Stability

>> Managing Preload Loss

Retrieval of Damaged Abutments

>> Retrieval Procedures

Future Developments in Dental Implant Technology

>> 3D Printing and Customization

>> Nanotechnology and Osseointegration

>> Smart Implants

Digital Implant Planning

>> Integration of Digital Technologies

Conclusion

FAQ

>> 1. What are the recommended torque values for Astra Tech abutment screws?

>> 2. What happens if the torque is too high?

>> 3. What are the consequences of too low torque?

>> 4. Why is it important to use a torque wrench?

>> 5. How often should torque wrenches be calibrated?

Citations:

The Astra Tech Implant System is widely used in dental implantology for its reliability and versatility. However, one critical aspect that can significantly impact the success of these implants is the torque applied to the abutment screws. Proper torque ensures the stability and longevity of the implant restoration, while incorrect torque can lead to complications such as screw loosening or fracture. In this article, we will explore the implications of applying too high or too low torque on Astra Tech abutment screws and provide insights into the recommended practices.

astra tech abutment screw torque

Introduction to Astra Tech Abutment Screws

Astra Tech abutment screws are designed to secure various types of abutments to dental implants. These screws are typically made from titanium or alloyed titanium to enhance strength and durability. The Astra Tech system offers a range of abutments, including healing abutments, temporary abutments, and final abutments like the Direct Abutment and Locator Abutment.

Recommended Torque Values

The recommended torque for Astra Tech abutment screws varies depending on the type of abutment and the implant size. For example:

- Temporary Abutments: Typically require a lower torque of 15 Ncm to ensure easy removal without damaging the implant or abutment.

- Final Abutments: Often require higher torques, such as 25 Ncm for most final abutments in the Astra Tech Implant System EV.

Consequences of Incorrect Torque

Too High Torque

Applying too high a torque can lead to several issues:

- Screw Fracture: Excessive force can cause the screw to break, especially if it is made from a material that is not sufficiently robust.

- Implant Damage: High torque can also damage the implant itself, particularly the internal threads, which can compromise the entire restoration.

- Abutment Deformation: The abutment may deform under excessive force, affecting its fit and function.

Too Low Torque

On the other hand, applying too low a torque can result in:

- Screw Loosening: Insufficient torque fails to secure the abutment properly, leading to screw loosening over time due to masticatory forces.

- Restoration Failure: Loose screws can cause the restoration to fail prematurely, necessitating additional dental work.

- Biological Complications: Chronic instability can lead to inflammation and bone loss around the implant.

Importance of Proper Torque

Proper torque is crucial for maintaining the integrity of the implant-abutment connection. It ensures that the screw is securely fastened without being over-tightened, which can lead to material failure. The use of a torque wrench is essential for achieving the precise torque recommended by the manufacturer.

Torque Wrenches for Astra Tech Implants

Astra Tech provides specific torque wrenches designed for their implant systems. These tools are calibrated to deliver the exact torque required for each type of abutment screw, minimizing the risk of over- or under-tightening.

astra ev abutment screw loosening

Clinical Considerations

In clinical practice, it is essential to follow the manufacturer's guidelines for torque values. Additionally, factors such as the type of abutment material (e.g., titanium vs. zirconia) and the design of the implant-abutment connection can influence the choice of torque.

Material Considerations

- Titanium Abutments: Generally stronger and more durable than zirconia, titanium abutments can withstand higher torques without deformation.

- Zirconia Abutments: More prone to plastic deformation and torque loosening, zirconia abutments require careful handling and lower torques.

Abutment Design

The design of the abutment also plays a crucial role in determining the appropriate torque. For instance, angled abutments may require specific handling to ensure proper seating and torque application.

Preload and Screw Stability

The stability of the screw is also influenced by the preload, which is the force generated when a screw is tightened to a specific torque. A higher preload generally results in better screw stability and reduced risk of loosening. However, factors such as surface roughness and settling effects can reduce the preload over time, potentially leading to screw loosening.

Managing Preload Loss

To manage preload loss, it is recommended to re-tighten the screws after a short period following initial tightening. This can help counteract the settling effect and maintain the desired preload.

Retrieval of Damaged Abutments

In cases where a screw fracture occurs, specialized tools such as the Fragment Fork are used to retrieve the screw fragment without damaging the implant threads. This involves careful manipulation and may require the removal of the abutment if the fragment cannot be retrieved.

Retrieval Procedures

1. Identify Implant Size: Determine the size of the implant to select the appropriate retrieval instruments.

2. Use Fragment Fork: Attach the Fragment Fork to the Restorative Driver Handle and rotate it counter-clockwise to loosen the screw fragment.

3. Remove Abutment if Necessary: If the fragment cannot be retrieved, use the Rescue Driver to remove the abutment and clean the threads.

Future Developments in Dental Implant Technology

The field of dental implantology is rapidly evolving, with advancements in materials, technologies, and techniques. Innovations such as 3D printing, nanotechnology, and smart implants are transforming the way dental implants are designed, manufactured, and integrated into patient care.

3D Printing and Customization

3D printing allows for the creation of highly customized implants tailored to each patient's unique anatomy. This technology enhances precision, reduces production time, and improves the fit and comfort of the implants[3][4].

Nanotechnology and Osseointegration

Nanotechnology is being used to enhance the surface characteristics of implants, promoting faster osseointegration and better integration with bone tissue. This results in more stable and durable implants[4][11].

Smart Implants

Smart implants integrate sensors and monitoring capabilities to provide real-time feedback on the health of the implant and surrounding tissues. This technology enables early detection of potential issues, such as infection or instability, allowing for timely intervention[7][11].

Digital Implant Planning

Digital technologies have revolutionized dental implant planning by providing precise and predictable outcomes. Software tools like exoplan and DTX Studio Implant enable comprehensive planning, including the design of surgical guides, which enhance the accuracy of implant placement[5][9].

Integration of Digital Technologies

- CBCT and Intraoral Scanning: These technologies allow for detailed imaging and precise planning of implant placement, ensuring optimal positioning and fit[12].

- Surgical Guides: Custom-made guides facilitate accurate implant placement, reducing the risk of complications and improving patient outcomes[12].

Conclusion

Applying the correct torque to Astra Tech abutment screws is vital for the success of dental implant restorations. Both too high and too low torque can lead to complications, emphasizing the need for precise torque control. By understanding the recommended torque values and using appropriate torque wrenches, dental professionals can ensure the longevity and stability of implant restorations. As technology continues to evolve, innovations in materials, digital planning, and smart implants will further enhance the efficiency and effectiveness of dental implant procedures.

ankylos implant abutment screw can not be removed

FAQ

1. What are the recommended torque values for Astra Tech abutment screws?

The recommended torque for Astra Tech abutment screws varies by implant size and type. For example, temporary abutments typically require 15 Ncm, while final abutments may need 25 Ncm depending on the system.

2. What happens if the torque is too high?

Too high a torque can cause screw fracture, implant damage, or abutment deformation. It is crucial to follow the manufacturer's guidelines to avoid these complications.

3. What are the consequences of too low torque?

Too low a torque can lead to screw loosening, restoration failure, and biological complications such as inflammation and bone loss around the implant.

4. Why is it important to use a torque wrench?

A torque wrench ensures that the exact recommended torque is applied, preventing over- or under-tightening of the abutment screws. This is critical for maintaining the integrity of the implant-abutment connection.

5. How often should torque wrenches be calibrated?

Torque wrenches should be recalibrated periodically, especially after sterilization, to ensure accuracy and prevent excessive torque that could damage the implant or restoration.

Citations:

[1] https://pmc.ncbi.nlm.nih.gov/articles/PMC6949338/

[2] https://avesis.yildiz.edu.tr/yayin/6638a749-3080-4411-b683-55a9ad690035/in-vitro-evaluation-of-manual-torque-values-applied-to-implant-abutment-complex-by-different-clinicians-and-abutment-screw-loosening

[3] https://www.trianglerestorationdentistry.com/dental-blog/the-future-of-dental-implants/

[4] https://southbaydental.com/15-innovations-in-dental-implant-and-their-materials/

[5] https://exocad.com/our-products/exoplan

[6] https://www.dynamicabutment.com/wp-content/uploads/sites/5/2019/02/10.1016@j.prosdent.2018.02.014-jpd.pdf

[7] https://smiledesigndentalfl.com/the-latest-advances-in-dental-implant-technology-for-2025/

[8] https://dentistmckinneytx.dental/blog/innovations-in-dental-implants-the-latest-techniques-and-materials

[9] https://www.dtxstudio.com/en-int/dtx-studio-implant

[10] https://www.straumann.com/anthogyr/en/home/equipment/implantology-surgery-equipment/torq-control.html

[11] https://www.insmyledental.com/exciting-innovations-of-dental-implants-in-2024/

[12] https://compendiumlive.com/2021/08/digital-implant-planning-and-surgical-guides-tools-for-clinical-success

[13] https://www.treedental.com/dental-automatic-implant-wrench-tr-ist06.html

[14] https://huanor-dental.en.made-in-china.com/product/PaxYiIdWCohZ/China-New-in-Automatic-Wireless-Digital-Dental-Implant-Electric-Torque-Wrench-with-Memory-Dental-Surgery-Equipment.html

[15] https://pubmed.ncbi.nlm.nih.gov/20163974/

[16] https://www.oatext.com/clinical-protocol-for-a-high-insertion-torque-immediate-implant-in-fresh-extraction-sites-a-3-year-audit.php

[17] https://shop.roedentallab.com/products/meg-torq-cordless-auto-torque-driver

[18] https://onlinelibrary.wiley.com/doi/abs/10.1111/jopr.13745

[19] https://implantleaguecourses.com/implant-surgery-techniques-dental-implant/

[20] https://www.mdpi.com/2673-4591/56/1/252

[21] https://www.straumann.com/dam/media-center/straumann/smart/com/en/smart-multi/product-descriptions/490.198-SmartM-Torque-Control-Device-en.pdf

[22] https://pubmed.ncbi.nlm.nih.gov/38068127/

[23] https://helixdental.com.au/what-to-expect-in-dental-implant-technology-in-2024/

[24] https://www.ddiidentistgosford.com.au/whats-new-in-dental-implants-for-2024/

[25] https://implastation.com

[26] https://www.archpointid.com/2024/04/25/the-future-of-dental-care-latest-advances-in-implant-technology/

[27] https://www.mdpi.com/1996-1944/16/23/7383

[28] https://www.3shape.com/en/software/implant-studio

[29] https://www.falconridgedental.com/innovations-in-dental-implant-technology-whats-new-in-2024/

[30] https://onlinelibrary.wiley.com/doi/toc/10.1155/2738.si.503125

[31] https://www.straumann.com/en/dental-professionals/digital/software/codiagnostix/codiagnostix-for-labs.html

[32] https://www.pallmalldental.co.uk/blog/bite-into-the-future-advancements-in-dental-implant-technology/

[33] https://www.pallmalldental.co.uk/blog/revolutionising-oral-health-the-latest-breakthroughs-in-dental-implant-materials/

[34] https://pmc.ncbi.nlm.nih.gov/articles/PMC2994679/

[35] https://dazzle.dental/blog/implant-surgery-precision-placement

[36] https://pmc.ncbi.nlm.nih.gov/articles/PMC5394346/

[37] https://www.avtecdental.com/collections/implant-torque-wrenches

CONTACT US

Shenzhen Yagu Dental Technology Co.,Ltd
  Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096
  Yagutech@hotmail.com
  8613631613096
 +8613631613096
Home
Copyright © Shenzhen Yagu Dental Technology Co.,Ltd
 Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096
  Yagutech@hotmail.com