Views: 222 Author: Dream Publish Time: 2025-04-19 Origin: Site
Content Menu
● Understanding Implant Abutment Screws
>> Anatomy of an Abutment Screw
● What Does It Mean When an Abutment Screw Is Stripped?
● Causes of Implant Abutment Screw Stripping
>> 1. Improper Driver Engagement
>> 2. Excessive Force or Torque
>> 3. Angled Abutments and Screw Channels
>> 4. Screw Loosening and Fatigue
>> 5. Debris and Contamination
>> 6. Poor Implant-Abutment Fit or Misfit
>> 7. Material and Design Factors
● Prevention of Abutment Screw Stripping
>> Use Manufacturer-Specified Drivers and Torque Wrenches
>> Confirm Screw Head Cleanliness
>> Apply Proper Torque and Preload
>> Avoid Excessive Occlusal Forces
>> Be Cautious with Angled Abutments
>> Routine Maintenance and Follow-Up
● Techniques for Removing a Stripped Implant Abutment Screw
>> 1. Create a Slot in the Screw Head
>> 2. Use Specialized Screw Removal Kits
>> 4. Manual Tools and Modified Drivers
>> 6. Surgical Removal as a Last Resort
● Challenges and Considerations
>> Case 1: Stripped Screw in a Maxillary Implant
>> Case 2: Angled Abutment Screw Stripping in a Mandibular Implant
● Frequently Asked Questions (FAQ)
>> 1. What is the main cause of implant abutment screw stripping?
>> 2. Can a stripped abutment screw be removed without damaging the implant?
>> 3. How can screw stripping be prevented during implant restoration?
>> 4. Are angled abutments more prone to screw stripping?
>> 5. What should a clinician do if the abutment screw is stripped during crown removal?
Dental implants have revolutionized restorative dentistry, offering patients durable and functional solutions for missing teeth. However, despite their high success rates, mechanical complications such as implant abutment screw stripped issues can occur, posing challenges to both clinicians and patients. Understanding the causes of abutment screw stripping, prevention strategies, and removal techniques is crucial for maintaining implant longevity and patient satisfaction.
The abutment screw is a critical component in the implant system that secures the abutment to the implant fixture embedded in the bone. It is designed to withstand significant forces but is susceptible to complications such as loosening, stripping, and fracture under certain conditions.
- Screw Head: The top portion engaged by the driver tool.
- Screw Shank: The cylindrical part extending from the head to the first thread.
- Threads: The helical ridges that engage with the internal threads of the implant body.
Stripping typically occurs at the screw head, where the driver engages, but fractures can also happen at the shank or threads.
A *stripped abutment screw* means the internal hex or other driver engagement feature on the screw head has been damaged or worn down, preventing the driver from properly gripping and turning the screw. This can happen during tightening or removal attempts and often complicates retrieval and repair.
Using a substitute or incorrect driver that does not perfectly match the screw head geometry is a common cause of stripping. The abutment screw head is designed with a hexalobular or hexagonal shape that requires precise engagement. Any mismatch or debris in the screw head can lead to poor contact and stripping when torque is applied.
Applying excessive force beyond the screw's design limits can deform or strip the screw head. This often occurs when clinicians use too much manual force or an inappropriate torque wrench, or when trying to loosen a screw that is tightly fixed or corroded.
Restorations with angled abutments or angled screw channels increase the risk of screw-head stripping. The off-axis torque application causes uneven stress on the screw head, making it more prone to damage during tightening or removal.
Repeated loosening and tightening cycles can cause metal fatigue and wear on the screw head, increasing the likelihood of stripping. Screw loosening itself is often caused by occlusal overload, bruxism, or improper prosthetic design, which concentrates stress on the screw.
Debris, cement remnants, or corrosion within the screw head can prevent full driver engagement, leading to stripping when torque is applied. Ensuring the screw head is clean prior to driver insertion is essential.
Misfit between the implant and abutment components can cause uneven stress distribution, increasing the risk of screw damage. Aftermarket or non-original components with less precise fit may contribute to this problem.
The material composition and design of the abutment screw also influence its susceptibility to stripping. Titanium screws are standard due to their strength and biocompatibility, but variations in alloy quality or surface treatment can affect durability. Additionally, smaller diameter screws or those with shallower driver engagement features are more prone to stripping.
Always use the exact driver and torque wrench recommended by the implant manufacturer to ensure proper engagement and correct torque application. Using non-standard drivers increases the risk of damaging the screw head and causing *implant abutment screw stripped* issues.
Before tightening or loosening, clean the screw head to remove any debris or cement that could interfere with driver engagement. Using alcohol wipes or ultrasonic cleaning can help ensure a clear interface.
- Preload is the initial tightening force that stretches the screw, securing the implant-abutment connection and reducing micro-movements.
- Use a calibrated torque wrench to apply the recommended torque, and retighten after 10 minutes to counteract embedment relaxation.
- Avoid exceeding the manufacturer's torque specifications, as excessive torque can strip the screw head or fracture the screw.
Design restorations to minimize cantilevers, flatten cuspal inclines, and center occlusal contacts to reduce stress on the screw. Patients with bruxism or parafunctional habits may require occlusal guards to protect the implant components.
Recognize the increased risk of screw stripping with angled abutments and take extra care during tightening and removal. Consider using abutments with improved anti-rotational features or angled screw channels designed to reduce stress.
Regular clinical and radiographic evaluations can detect early signs of screw loosening or wear. Early intervention can prevent the progression to screw stripping or fracture.
Removing a stripped screw requires careful technique to avoid damaging the implant's internal threads.
Using a small round bur, create a slot on the screw head to enable engagement with a flathead or slot driver for removal. This method is effective when enough of the screw head remains intact.
Many manufacturers offer kits with reverse-threaded drills and taps designed to grip and back out broken or stripped screws without damaging the implant. These kits often include:
- Reverse drills to create purchase points.
- Extraction taps to engage the screw fragment.
- Screwdrivers designed for stripped screw heads.
A reverse (counterclockwise) drill is used to create a dimple or groove in the screw fragment, allowing a tap drill to engage and unscrew the fragment. This technique requires precision and patience.
Customized small screwdrivers or modified burs can be used to engage grooves cut into the screw fragment for removal by anticlockwise rotation. Sometimes, dental explorers or ultrasonic tips assist in loosening the screw.
- Use lubricants like denture cleaning solutions or silicone grease to loosen debris and reduce friction before attempting removal.
- Wooden sticks from cotton swabs can sometimes grip and rotate loose fragments gently.
If all conservative methods fail and the screw cannot be removed without damaging the implant, surgical intervention to remove and replace the implant may be necessary. This is the least desirable option due to increased patient morbidity and cost.
- Removal of stripped screws can be time-consuming and technically demanding.
- Damage to the implant's internal threads can necessitate implant removal and replacement, increasing patient morbidity.
- Early identification and prevention are key to avoiding complex retrieval procedures.
- Communication with the patient regarding risks and treatment options is essential to manage expectations.
A 55-year-old patient presented with a loose crown on a maxillary implant. During screw removal, the abutment screw became stripped due to excessive torque and debris in the screw head. Using a screw retrieval kit and creating a groove with a bur, the clinician successfully removed the screw without implant damage. The screw was replaced, and the prosthesis was re-cemented with proper torque application.
A patient with an angled abutment experienced screw loosening and stripping after repeated tightening attempts. The clinician used a reverse drill technique to remove the stripped screw and replaced it with a new screw of improved design. Occlusal adjustments were made to reduce lateral forces, preventing recurrence.
Implant abutment screw stripped complications arise primarily from improper driver engagement, excessive torque, angled abutments, screw loosening, and debris contamination. Prevention hinges on using manufacturer-specific tools, proper torque application, and careful prosthetic design to minimize stress on the screw. When stripping occurs, specialized removal techniques and kits are essential to preserve the implant and restore function. Understanding these factors helps clinicians manage and prevent this challenging complication, ensuring long-term implant success.
The primary cause is improper engagement of the driver with the screw head, often due to using a substitute driver or debris in the screw head, combined with excessive torque application.
Yes, with specialized screw removal kits and careful techniques such as creating a slot in the screw head or using reverse drills, it is often possible to remove the screw without harming the implant internal threads.
Prevention includes using the correct manufacturer-specified driver and torque wrench, ensuring the screw head is clean, applying the recommended torque preload, and avoiding excessive occlusal forces.
Yes, angled abutments increase the risk because torque is applied off-axis, leading to uneven stress and higher likelihood of stripping the screw head.
The clinician should avoid forcing the screw out with improper tools, use a screw removal kit or create a groove in the screw head to engage a flat driver, and proceed carefully to prevent implant damage.
[1] https://www.journalofosseointegration.eu/jo/article/download/502/358
[2] https://pubmed.ncbi.nlm.nih.gov/20875525/
[3] https://dimensionsofdentalhygiene.com/preventing-screw-complications-in-implant-restorations/
[4] https://www.youtube.com/watch?v=SgVWQTcFMLY
[5] https://www.youtube.com/watch?v=f7zO0FgkqSM
[6] https://uniqa.dental/cases/removing-broken-screw-dental-implant-guide-dentists/
[7] https://www.perioimplantadvisory.com/clinical-tips/periodontal-complications/article/16412213/a-solution-for-stripped-dental-implant-screws
[8] https://resnikimplantinstitute.com/blog/management-of-fractured-abutment-screws/
[9] https://uniqa.dental/cases/what-to-do-if-the-screw-in-the-implant-breaks/
[10] https://burbankdentalimplants.com/how-to-fix-a-broken-dental-implant-screw-a-case-report-burbank-dentist-ramsey-amin-dds-explains/
[11] https://www.youtube.com/watch?v=IDh-a2Wr9fI
[12] https://advanceddentistryinstitute.com.au/understanding-implant-crown-screw-loosening/
[13] https://pmc.ncbi.nlm.nih.gov/articles/PMC4148504/
[14] https://www.perioimplantadvisory.com/dental-implants/article/14200668/my-dental-implant-screw-loosened-did-i-miss-something
[15] https://www.mdpi.com/2079-4983/15/4/96
[16] https://pmc.ncbi.nlm.nih.gov/articles/PMC7842481/
[17] https://www.youtube.com/watch?v=lDQnGRoPfWU
[18] https://saspublishers.com/media/articles/SJDS_43109-111.pdf
[19] https://www.mdpi.com/1996-1944/17/20/5053
[20] https://www.sciencedirect.com/science/article/abs/pii/S0022391323004158
[21] https://jcda.ca/article/e22
[22] https://implantationdentalcenter.com/2017/02/17/stripped-screw/
[23] https://www.sciencedirect.com/science/article/pii/S0022391320305059
[24] https://www.shutterstock.com/search/implant-screw
[25] https://www.istockphoto.com/photos/abutment
[26] https://www.instagram.com/yeoh_ot_prosthodontist/p/DAYnM_4TkMk/?locale=ne_NP
[27] https://www.youtube.com/watch?v=abdqKua24w4
[28] https://www.youtube.com/watch?v=FOxzzonf8bY
[29] https://www.pinterest.com/pin/3-techniques-to-remove-broken-abutment-screws--292804413258464542/
[30] https://www.youtube.com/watch?v=BkfPZ1PUSCE
[31] https://www.youtube.com/watch?v=-PfwEPfZ5vc
[32] https://www.youtube.com/watch?v=cuQf5LIVG7w
[33] https://burbankdentalimplants.com/can-dental-implants-be-removed-video/
[34] https://www.youtube.com/watch?v=OGfaLRjXvpQ
[35] https://www.bitesinstitute.com/forums/138/threads/329
[36] https://www.reddit.com/r/Dentistry/comments/1fehh84/stuck_cover_screw/
[37] https://www.realself.com/question/newport-beach-ca-fixing-loose-inplant-dentist-stripped-screw-head
[38] https://dimensionsofdentalhygiene.com/preventing-screw-complications-in-implant-restorations/
[39] https://www.yagudentaltech.com/how-long-does-abutment-screw-removal-take.html
[40] https://www.osseonews.com/abutment-screw-gets-stuck/
[41] https://pmc.ncbi.nlm.nih.gov/articles/PMC11050945/
[42] https://www.osseonews.com/dental-implant-restorations-internal-thread-complications/
[43] https://www.orthobullets.com/video/view?id=104429
[44] https://www.youtube.com/watch?v=017o038ua3g
[45] https://images.aofoundation.org/CIP/asset/download/Gallery/13042
What Are The Common Complications From Stripped Abutment Screws?
What Is The Difference Between Titanium And Gold Straumann Abutment Screws?
Are Straumann Abutment Torque Values Different For Custom And Standard Abutments?
How Effective Is The Straumann Screw Removal Kit For Dental Implants?
Can Stainless Steel Abutment Screws Be Used In All Implant Systems?
How Do You Replace A Short Abutment Screw In Hiossen Implants?