 +8613631613096    Yagutech@hotmail.com 
You are here: Home » News » What Are The Main Causes of Abutment Screw Fracture?

What Are The Main Causes of Abutment Screw Fracture?

Views: 222     Author: Dream     Publish Time: 2025-03-05      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Content Menu

Introduction to Abutment Screw Fractures

>> Causes of Abutment Screw Fractures

Retrieval Techniques for Fractured Abutment Screws

>> Conservative Approaches

>> Commercial Retrieval Kits

Prevention Strategies

Advanced Materials and Designs

>> Titanium Alloys

>> Innovative Implant Designs

Clinical Case Studies

>> Case Study Example

Patient Factors and Abutment Screw Fractures

>> Bruxism

>> Parafunctional Habits

Conclusion

Frequently Asked Questions

>> 1. What are the common causes of abutment screw fractures?

>> 2. How are fractured abutment screws typically retrieved?

>> 3. What are some strategies to prevent abutment screw fractures?

>> 4. What is the incidence of abutment screw fractures?

>> 5. How does occlusal interference contribute to abutment screw fractures?

Citations:

Abutment screw fractures are a significant complication in dental implantology, affecting the stability and longevity of implant-supported restorations. Understanding the causes of these fractures is crucial for preventing them and ensuring successful outcomes in dental implant treatments. This article will delve into the primary causes of abutment screw fractures, discuss retrieval techniques, and provide insights into prevention strategies.

abutment screw fracture

Introduction to Abutment Screw Fractures

Abutment screw fractures occur when the screw that connects the abutment to the dental implant breaks. This can happen due to various biomechanical factors, including improper fit of the prosthesis, inadequate seating of the abutment, occlusal interference, and manufacturing errors. The incidence of abutment screw fractures is relatively low, ranging from 0.5% to 8%.

Causes of Abutment Screw Fractures

1. Improper Fit of the Prosthesis: A non-passive fit of the superstructure can lead to uneven distribution of forces, causing stress on the abutment screw and increasing the risk of fracture. This is often due to inaccuracies in the impression process or errors during the fabrication of the prosthesis.

2. Inadequate Seating of the Abutment: If the abutment is not properly seated on the implant, it can lead to screw loosening and eventual fracture. Proper seating ensures that the screw is not subjected to unnecessary stress.

3. Occlusal Interference: Premature occlusal contacts can subject the abutment screw to excessive forces, leading to fatigue and fracture over time. Adjusting the occlusion to eliminate these premature contacts is essential.

4. Manufacturing Errors: Defects in the screw or abutment design can weaken the structure, making it more susceptible to fracture. High-quality materials and precise manufacturing processes are crucial to minimize these risks.

5. Biomechanical Overloading: Excessive masticatory forces, especially in the posterior regions, can overload the abutment screw, leading to fracture. This is particularly relevant in cases where the implant is subjected to high occlusal forces due to factors like bruxism.

Retrieval Techniques for Fractured Abutment Screws

Retrieving a fractured abutment screw is challenging and requires careful techniques to avoid damaging the implant. Various methods are employed, including conservative approaches and the use of commercial retrieval kits.

Conservative Approaches

- Manual Removal: If the fracture occurs above the implant body, the screw fragment can be grasped with a hemostat or removed using a sharp explorer in a counterclockwise motion. This method is simple but requires precision to avoid pushing the fragment further into the implant.

- Screw Removal Tools: Specialized tools like the Argon abutment removal tool can be used to remove the fractured screw by screwing the tool in a counterclockwise direction to free the screw fragment. These tools are designed to engage the screw head or threads.

Commercial Retrieval Kits

These kits often include drills and taps designed to engage the fractured screw and remove it without damaging the implant. However, they can be expensive and may not always be effective. The choice of retrieval method depends on the extent and location of the fracture.

managing patients with a loose implant abutment screw

Prevention Strategies

Preventing abutment screw fractures involves addressing the underlying causes:

1. Proper Prosthesis Fit: Ensuring a passive fit of the superstructure is crucial to distribute forces evenly. This can be achieved through accurate impressions and precise prosthesis fabrication.

2. Correct Abutment Seating: Proper seating of the abutment on the implant is essential to prevent screw loosening. This involves ensuring that the abutment is fully seated and the screw is tightened with the appropriate torque.

3. Occlusal Adjustment: Adjusting the occlusion to eliminate premature contacts can reduce stress on the abutment screw. Regular occlusal checks are important to maintain optimal occlusal relationships.

4. Use of Appropriate Torque: Using the correct torque when tightening the abutment screw can prevent over-tightening, which can lead to fracture. Manufacturers often provide specific torque recommendations for their products.

5. Regular Maintenance: Regular check-ups can help identify potential issues before they lead to screw fracture. This includes monitoring for signs of screw loosening or occlusal changes.

Advanced Materials and Designs

Recent advancements in materials and designs aim to reduce the incidence of abutment screw fractures. For instance, the use of titanium alloys with improved strength and corrosion resistance can enhance the durability of the screws. Additionally, some implants feature designs that distribute forces more evenly, reducing stress on the abutment screw.

Titanium Alloys

Titanium alloys are widely used in dental implants due to their biocompatibility, strength, and resistance to corrosion. Newer alloys have been developed with enhanced mechanical properties, making them more resistant to fracture.

Innovative Implant Designs

Some modern implant designs incorporate features that help distribute occlusal forces more evenly. These designs can reduce the stress on the abutment screw, potentially lowering the risk of fracture.

Clinical Case Studies

Clinical case studies provide valuable insights into the management and prevention of abutment screw fractures. These studies often highlight the importance of proper technique and the role of patient factors, such as bruxism, in increasing the risk of fracture.

Case Study Example

A clinical case involving a patient with a history of bruxism demonstrated the importance of occlusal adjustment in preventing abutment screw fractures. By adjusting the occlusion to reduce premature contacts, the stress on the abutment screw was significantly reduced, preventing fracture.

Patient Factors and Abutment Screw Fractures

Patient factors, such as bruxism and parafunctional habits, can significantly increase the risk of abutment screw fractures. These habits can subject the implant to excessive forces, leading to increased stress on the abutment screw.

Bruxism

Bruxism, or grinding of the teeth, is a common parafunctional habit that can lead to increased occlusal forces. Patients with bruxism require careful management, including occlusal adjustments and possibly the use of night guards to reduce the impact of grinding on the implants.

Parafunctional Habits

Other parafunctional habits, such as clenching or biting on hard objects, can also increase the risk of abutment screw fractures. Educating patients about these risks and providing them with strategies to manage these habits is important.

Conclusion

Abutment screw fractures are a significant concern in dental implantology, primarily caused by biomechanical factors such as improper prosthesis fit, inadequate abutment seating, occlusal interference, and manufacturing errors. Understanding these causes and employing effective retrieval and prevention strategies are crucial for maintaining the integrity of implant-supported restorations.

abutment screw fell out

Frequently Asked Questions

1. What are the common causes of abutment screw fractures?

Abutment screw fractures are commonly caused by improper fit of the prosthesis, inadequate seating of the abutment, occlusal interference, and manufacturing errors.

2. How are fractured abutment screws typically retrieved?

Fractured abutment screws can be retrieved using conservative methods like manual removal or specialized tools, as well as commercial retrieval kits designed to engage and remove the screw without damaging the implant.

3. What are some strategies to prevent abutment screw fractures?

Prevention strategies include ensuring a proper fit of the prosthesis, correct seating of the abutment, occlusal adjustment, using appropriate torque, and regular maintenance.

4. What is the incidence of abutment screw fractures?

The incidence of abutment screw fractures ranges from 0.5% to 8%.

5. How does occlusal interference contribute to abutment screw fractures?

Occlusal interference can subject the abutment screw to excessive forces, leading to fatigue and eventual fracture over time.

Citations:

[1] https://pmc.ncbi.nlm.nih.gov/articles/PMC9369788/

[2] https://www.youtube.com/watch?v=NhSGExGIyQI

[3] https://meridian.allenpress.com/joi/article/42/6/508/2450/Management-of-a-Fractured-Implant-Abutment-Screw

[4] https://www.journalofosseointegration.eu/jo/article/download/502/358/3547

[5] https://www.ijoprd.com/doi/IJOPRD/pdf/10.5005/jp-journals-10019-1389

[6] https://www.youtube.com/watch?v=4ztRAVBA4zM

[7] https://www.journalofosseointegration.eu/jo/article/download/502/358

[8] https://pmc.ncbi.nlm.nih.gov/articles/PMC8425375/

[9] https://www.perioimplantadvisory.com/clinical-tips/prosthodontic-complications/video/14209641/how-to-remove-a-loose-or-fractured-implant-abutment-screw

[10] https://pubmed.ncbi.nlm.nih.gov/35966908/

CONTACT US

Shenzhen Yagu Dental Technology Co.,Ltd
  Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096
  Yagutech@hotmail.com
  8613631613096
 +8613631613096
Home
Copyright © Shenzhen Yagu Dental Technology Co.,Ltd
 Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096