How Does Preload Affect Implant Abutment Screw Stability?

Views: 222     Author: Dream     Publish Time: 2025-04-27      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Content Menu

What Is Preload in Implant Abutment Screws?

How Preload Influences Screw Stability

>> 1. Maintaining Joint Integrity

>> 2. Preventing Screw Loosening

>> 3. Fatigue Resistance

>> 4. Minimizing Microleakage

Factors Affecting Preload and Screw Stability

>> 1. Applied Torque

>> 2. Retightening Protocol

>> 3. Screw Material and Coating

>> 4. Screw and Thread Design

>> 5. Connection Type

>> 6. Surface Condition and Lubrication

Clinical Implications of Preload on Implant Abutment Screw Stability

>> Optimizing Preload for Longevity

>> Consequences of Inadequate Preload

Conclusion

Frequently Asked Questions (FAQ)

>> 1. What is the ideal torque value for implant abutment screws?

>> 2. Why is retightening the abutment screw important?

>> 3. How does screw material affect preload?

>> 4. Can repeated use of the same abutment screw affect preload?

>> 5. How does implant-abutment connection type influence preload maintenance?

Citations:

Dental implants have revolutionized restorative dentistry, providing patients with durable and functional tooth replacements. A critical factor in the long-term success of dental implants is the stability of the implant-abutment connection, which is primarily maintained by the preload applied to the abutment screw. This article explores in depth how preload affects implant abutment screw stability, the mechanisms involved, factors influencing preload, clinical implications, and best practices for optimizing implant longevity.

preload implant abutment screw

What Is Preload in Implant Abutment Screws?

Preload is the axial tension generated within an abutment screw when a specific torque is applied during tightening. When the screw is torqued, it elongates slightly, creating a clamping force that pulls the abutment and implant fixture tightly together. This clamping force resists separation and micromovement at the implant-abutment interface, which is essential for maintaining joint stability under functional loads such as chewing.

- Mechanism: Torque applied to the screw head induces elongation of the screw shaft, which produces tension (preload). The elastic recovery of the screw material creates a compressive clamping force between the implant and abutment components[2][7][12].

- Importance: Adequate preload prevents screw loosening by ensuring the joint remains stable despite dynamic occlusal forces. Insufficient preload leads to micromovement, screw loosening, and potential biological complications due to microgaps[7][8].

How Preload Influences Screw Stability

1. Maintaining Joint Integrity

A properly preloaded screw holds the implant and abutment components firmly together, reducing micromovements that can cause screw loosening or fracture. The preload must be sufficient to counteract the forces generated during mastication, which can otherwise overcome the clamping force and cause loosening[7][8].

2. Preventing Screw Loosening

Screw loosening is one of the most common mechanical complications in implant prosthodontics. It occurs when the applied forces exceed the preload-induced clamping force, causing the screw to gradually back out. Maintaining optimal preload minimizes this risk[1][9][14].

3. Fatigue Resistance

Preload improves the fatigue resistance of the implant-abutment connection. The tension in the screw distributes occlusal loads more evenly and reduces stress concentrations that can lead to screw fatigue and fracture[8][14].

4. Minimizing Microleakage

A stable implant-abutment interface with adequate preload reduces microgaps where bacteria can colonize, thus preventing peri-implantitis and other biological complications[5][8].

Factors Affecting Preload and Screw Stability

1. Applied Torque

The magnitude of the tightening torque directly influences the preload. Increasing torque generally increases preload and stability, but excessive torque risks screw fracture or thread stripping. Most manufacturers recommend specific torque values, often around 30-35 Ncm, to optimize preload without damaging components[1][2][4][7].

2. Retightening Protocol

Due to the "settling effect" or "embedment relaxation," 2-10% of preload is lost shortly after initial tightening as microscopic surface irregularities flatten under load. Retightening the screw 10 minutes after initial torque application restores lost preload and is recommended as a routine clinical practice[1][2][13].

3. Screw Material and Coating

Gold screws generally produce higher and more consistent preload than titanium screws, likely due to differences in friction and material properties. However, titanium screws are also widely used due to biocompatibility. Coated screws (e.g., carbon-coated) may lose preload with repeated use due to increased friction[3][4][10][15].

4. Screw and Thread Design

Screw head angle and thread design affect preload. Studies show tightening torque and screw head angle significantly influence preload force, whereas the number of threads has less effect[15]. Screw geometry also impacts the distribution of stress and resistance to loosening.

5. Connection Type

Internal connections (e.g., internal hexagon, Morse taper) generally maintain preload better and resist loosening more effectively than external hex connections due to better mechanical interlocking and load distribution[6][11][14].

6. Surface Condition and Lubrication

Surface roughness and friction between the screw and implant threads affect preload. Lubrication reduces friction, allowing higher preload at the same torque. Repeated tightening without lubrication can increase friction and reduce achievable preload[3][5][14].

percentage of chance abutment screw breaks

Clinical Implications of Preload on Implant Abutment Screw Stability

Optimizing Preload for Longevity

- Use calibrated torque devices to apply manufacturer-recommended torque values precisely. Deviations greater than 6% can lead to under- or over-tightening, risking loosening or screw fracture[9][14].

- Retighten screws 10 minutes after initial torque to compensate for settling effects and regain preload[1][2][13].

- Select appropriate screw materials and designs that maximize preload and fatigue resistance. Gold screws may offer superior preload but titanium screws are commonly used due to biocompatibility and mechanical properties[4][10].

- Consider implant-abutment connection type when planning treatment, favoring internal connections for better preload maintenance and stability[6][11].

- Avoid repeated reuse of coated screws without replacement, as friction increases and preload decreases with each tightening cycle[3][5].

Consequences of Inadequate Preload

- Screw loosening leading to prosthesis mobility, discomfort, and potential implant failure.

- Microgaps allowing bacterial infiltration, causing peri-implant mucositis or peri-implantitis.

- Increased risk of screw fracture due to fatigue from micromotion.

- Need for unscheduled maintenance visits, increasing patient cost and treatment time[8][9][14].

Conclusion

Preload is a critical biomechanical factor that directly influences the stability and longevity of implant abutment screw connections. Adequate preload, achieved by applying the correct torque and retightening after settling, ensures a strong clamping force that resists occlusal forces, prevents screw loosening, and minimizes biological complications. Factors such as screw material, design, connection type, and surface conditions also affect preload and should be carefully considered in clinical practice. Adhering to best practices for preload application optimizes implant success and patient outcomes.

osstem implant abutment screw hex

Frequently Asked Questions (FAQ)

1. What is the ideal torque value for implant abutment screws?

The ideal torque typically ranges from 30 to 35 Ncm, depending on the implant system manufacturer's recommendations. Applying torque within this range maximizes preload without risking screw damage[1][2][4].

2. Why is retightening the abutment screw important?

Retightening 10 minutes after initial torque compensates for the settling effect, where microscopic surface irregularities flatten and cause preload loss. This practice restores preload and reduces the risk of loosening[1][2][13].

3. How does screw material affect preload?

Gold screws generally achieve higher preload values than titanium screws due to lower friction and better material properties. However, titanium screws are widely used for their biocompatibility and mechanical strength[4][10].

4. Can repeated use of the same abutment screw affect preload?

Yes. Studies show that repeated tightening of coated screws increases friction, reducing preload and compromising screw stability. It is advisable to replace screws after multiple uses[3][5].

5. How does implant-abutment connection type influence preload maintenance?

Internal connections (e.g., internal hex, Morse taper) maintain preload better and resist screw loosening more effectively than external hex connections due to improved mechanical engagement and load distribution[6][11][14].

Citations:

[1] https://pubmed.ncbi.nlm.nih.gov/12498448/

[2] https://meridian.allenpress.com/joi/article-pdf/28/2/67/2032852/1548-1336(2002)028_0067_trbipa_2_3_co_2.pdf

[3] https://pubmed.ncbi.nlm.nih.gov/36947262/

[4] http://www.scielo.org.za/scielo.php?script=sci_arttext&pid=S0011-85162014000700006

[5] https://pmc.ncbi.nlm.nih.gov/articles/PMC10033796/

[6] https://pmc.ncbi.nlm.nih.gov/articles/PMC5741850/

[7] https://adi.org.uk/resources/surgical_stage_prosthetic_treatment_pre-load/

[8] https://pmc.ncbi.nlm.nih.gov/articles/PMC4668729/

[9] https://www.perioimplantadvisory.com/dental-implants/article/14200668/my-dental-implant-screw-loosened-did-i-miss-something

[10] https://pmc.ncbi.nlm.nih.gov/articles/PMC4327281/

[11] https://dynadental.com/wp-content/uploads/2023/11/2017-Pardal-Pelaez-B-Montero-J-Preload-loss-of-abutment-screws-after-dynamique-fatigue-in-single-implant-supported-restorations.pdf

[12] https://pocketdentistry.com/28-principles-for-abutment-and-prosthetic-screws-and-screw-retained-components-and-prostheses/

[13] https://totalimplantcare.iess.dental/wp-content/uploads/2024/06/06_2020_Varvara_The-Relationship-Between-Time-of-Retightening-and-Preload-Loss-of-Abutment-Screws-for-Two-Different-Implant-Designs-An-In-Vitro-Study.pdf

[14] https://pmc.ncbi.nlm.nih.gov/articles/PMC6070846/

[15] https://www.quintessence-publishing.com/gbr/en/article/847099/the-international-journal-of-oral-maxillofacial-implants/2018/02/effects-of-screw-configuration-on-the-preload-force-of-implant-abutment-screws

[16] https://www.sciencedirect.com/science/article/pii/S2772414X22000068

[17] https://www.mdpi.com/1996-1944/15/4/1392

[18] https://pubmed.ncbi.nlm.nih.gov/29534122/

[19] https://www.sciencedirect.com/science/article/abs/pii/S0022391319303506

[20] https://www.sciencedirect.com/science/article/pii/S1751616123005180

[21] https://pubmed.ncbi.nlm.nih.gov/7590997/

[22] https://www.springermedizin.de/preload-and-friction-in-an-implant-abutment-screw-complex-includ/24662082

[23] https://www.sciencedirect.com/science/article/pii/S0022391319303506

[24] https://www.mdpi.com/1996-1944/17/6/1414

[25] https://onlinelibrary.wiley.com/doi/pdf/10.1002/9781119399186.ch31

[26] https://www.implacom.nl/assets/admin/plugins/kcfinder/upload/files/Literatuurstudies/Implant%20screw%20mechanics%20and%20the%20settling%20effec.pdf

[27] https://www.sciencedirect.com/science/article/pii/S2212426824001519

[28] https://dynadental.com/wp-content/uploads/2023/11/2017-Pardal-Pelaez-B-Montero-J-Preload-loss-of-abutment-screws-after-dynamique-fatigue-in-single-implant-supported-restorations.pdf

[29] https://www.jstage.jst.go.jp/article/jpr/advpub/0/advpub_JPR_D_24_00064/_article

[30] https://www.academia.edu/61560714/Preload_Coefficient_of_Friction_and_Thread_Friction_in_an_Implant_Abutment_Screw_Complex

[31] https://www.youtube.com/watch?v=ST9DssVLGcU

[32] https://www.youtube.com/watch?v=lDQnGRoPfWU

[33] https://www.sciencedirect.com/science/article/abs/pii/S0022391303006723

[34] https://www.youtube.com/watch?v=TUB3rIgiXbk

[35] https://www.youtube.com/watch?v=SOOC2edVDic

[36] https://pmc.ncbi.nlm.nih.gov/articles/PMC5741850/

[37] https://denpedia.com/abutment-screw-loosening-in-dental-implants/

[38] https://www.quintessence-publishing.com/anz/en/article/844048/the-international-journal-of-oral-maxillofacial-implants/1995/05/elongation-and-preload-stress-in-dental-lmplant-abutment-screws

[39] https://www.nobelbiocare.com/en-ie/technical-support-frequently-asked-questions-faqs

[40] https://japid.tbzmed.ac.ir/Inpress/japid-1164.pdf

[41] https://pmc.ncbi.nlm.nih.gov/articles/PMC6070846/

[42] https://www.spotimplant.com/en/knowledge-base/abutment-screw-torque-and-driver/

[43] https://clinicablasi.com/en/process-of-a-dental-implant/

[44] https://decisionsindentistry.com/article/reducing-risk-implant-abutment-screw-loosening/

[45] https://www.nobelbiocare.com/en-int/top-questions-frequently-asked-questions-faqs

[46] https://www.youtube.com/watch?v=bAtcvqeb53g

[47] https://www.youtube.com/watch?v=l8GBokqFK5I

[48] https://www.youtube.com/watch?v=UyN2r6Nl9Rk

[49] https://pubmed.ncbi.nlm.nih.gov/39358213/

[50] https://www.youtube.com/watch?v=8S-3716PjQE

CONTACT US

Shenzhen Yagu Dental Technology Co.,Ltd
  Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096
  Yagutech@hotmail.com
  8613631613096
 +8613631613096
Home
Copyright © Shenzhen Yagu Dental Technology Co.,Ltd
 Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096
  Yagutech@hotmail.com