Content Menu

Introduction to Dental Implant Systems

>> BioHorizons Implant System

>>> BioHorizons Abutment Screws

>> Nobel Biocare Implant System

>>> Nobel 1.25 Hex Screw

Compatibility of Nobel 1.25 Hex Screw with BioHorizons Abutments

>> Technical Specifications

>> Practical Considerations

Torque Specifications

Detailed Analysis of Compatibility

>> Case Studies

Clinical Implications

Expanded Practical Implications

>> Additional Practical Implications to Consider

>> Table: Comparison of BioHorizons and Nobel Biocare Implant Systems

>> Additional Considerations

Conclusion

FAQ

>> 1. What is the standard hex driver size for BioHorizons abutments?

>> 2. Can I use a Nobel 1.25 hex screw with BioHorizons abutments?

>> 3. What is the recommended torque for BioHorizons internal hex implants?

>> 4. What are the risks of using incompatible abutment screws?

>> 5. How do I ensure compatibility between different dental implant components?

Citations:

Dental implants have become a standard solution for tooth loss, offering both functional and aesthetic benefits. Among the various components involved in dental implant systems, abutment screws play a crucial role in securing the abutment to the implant. This article explores whether a Nobel 1.25 hex screw can be used with BioHorizons abutments, delving into the compatibility and technical specifications of these components.

biohorizon nobel 1.25 hex abutment screw

Introduction to Dental Implant Systems

Dental implant systems consist of three main components: the implant itself, the abutment, and the prosthetic crown. The implant is surgically placed into the jawbone, while the abutment connects the implant to the prosthetic crown. The abutment screw is essential for securing the abutment to the implant.

BioHorizons Implant System

BioHorizons offers a range of dental implants with internal hex connections, which are compatible with specific abutment screws. These implants are designed for optimal integration with the surrounding bone and feature a tapered internal hex design for secure abutment placement.

BioHorizons Abutment Screws

BioHorizons abutments typically use a 0.050” (1.25 mm) hex driver for screwing the abutment onto the implant. This driver size is standard for BioHorizons internal hex implants, ensuring a secure fit and proper torque application.

Nobel Biocare Implant System

Nobel Biocare is another prominent manufacturer of dental implants, known for its innovative designs and compatibility with various abutment systems. Their implants often use a Unigrip connection, but they also offer systems compatible with hex drivers.

Nobel 1.25 Hex Screw

The Nobel 1.25 hex screw is designed for use with specific Nobel Biocare implants that have a compatible hex interface. However, the primary question is whether this screw can be used with BioHorizons abutments.

Compatibility of Nobel 1.25 Hex Screw with BioHorizons Abutments

To determine if a Nobel 1.25 hex screw can be used with BioHorizons abutments, we need to consider the compatibility of the screw's dimensions and the abutment's internal hex design.

Technical Specifications

- BioHorizons Abutments: These typically require a 0.050” (1.25 mm) hex driver for secure placement.

- Nobel 1.25 Hex Screw: This screw is designed for use with Nobel Biocare implants that have a compatible hex interface.

Given that both systems use a 1.25 mm hex interface, theoretically, the Nobel 1.25 hex screw could be compatible with BioHorizons abutments if the specific implant design allows for it. However, compatibility should be confirmed by the manufacturer or through detailed technical specifications to ensure proper fit and function.

Practical Considerations

In practice, using a screw from one manufacturer with another's abutments can lead to issues with fit, torque, and overall stability. It is crucial to follow the manufacturer's recommendations to avoid complications.

biohorizon abutment screw torque

Torque Specifications

When using any abutment screw, applying the correct torque is essential to prevent damage to the implant or abutment. BioHorizons recommends a torque of 30 Ncm for their internal hex implants.

Detailed Analysis of Compatibility

To further assess compatibility, consider the following factors:

1. Material Compatibility: Ensure that the materials used in both the screw and the abutment are compatible and will not cause corrosion or wear issues over time.

2. Thread Design: The thread design of the screw must match the internal threads of the abutment to ensure a secure and stable connection.

3. Length and Diameter: The length and diameter of the screw must be appropriate for the abutment and implant to avoid over-tightening or insufficient tightening.

Case Studies

There have been instances where clinicians have successfully used screws from different manufacturers with compatible interfaces. However, these cases often involve careful selection and verification of compatibility.

Clinical Implications

In clinical practice, using a Nobel 1.25 hex screw with BioHorizons abutments could potentially offer flexibility in inventory management and reduce costs. However, any deviation from recommended components should be approached cautiously to avoid compromising the integrity of the implant system.

Expanded Practical Implications

In practice, dental clinicians often face challenges when dealing with different implant systems. Ensuring compatibility between components from different manufacturers can be complex and requires careful consideration of technical specifications.

Additional Practical Implications to Consider

1. Inventory Management: Using a Nobel 1.25 hex screw with BioHorizons abutments can simplify inventory management for dental practices. By having a compatible screw on hand, clinicians can reduce the number of different components they need to stock, leading to cost savings and increased efficiency.

2. Flexibility in Treatment Options: Clinicians may find that using a Nobel 1.25 hex screw with BioHorizons abutments allows for greater flexibility in treatment options. This compatibility can enable the use of different implant systems within the same practice, accommodating a wider range of patient needs.

3. Risk of Complications: While compatibility is theoretically possible, the risk of complications remains. Clinicians should be aware of potential issues such as screw loosening, improper fit, and the impact on long-term stability. It is essential to monitor patients closely after using components from different manufacturers.

4. Patient Education: Educating patients about the components used in their dental implants is crucial. Clinicians should explain the rationale behind using a Nobel 1.25 hex screw with BioHorizons abutments and address any concerns patients may have about compatibility and potential risks.

5. Regulatory Considerations: Clinicians should also be aware of any regulatory considerations when using components from different manufacturers. Compliance with local regulations and guidelines is essential to ensure patient safety and avoid legal issues.

Table: Comparison of BioHorizons and Nobel Biocare Implant Systems

Feature BioHorizons Nobel Biocare
Hex Size 1.25 mm 1.25 mm
Torque Recommendation 30 Ncm Varies by model
Material Titanium Titanium

Additional Considerations

- Sterilization: Ensure that any screw used is properly sterilized before application to prevent infection.

- Warranty and Support: Using components from different manufacturers might affect warranty coverage and technical support.

By considering these factors, clinicians can make informed decisions about using a Nobel 1.25 hex screw with BioHorizons abutments, ensuring optimal outcomes for patients.

Conclusion

While the Nobel 1.25 hex screw and BioHorizons abutments share a compatible hex size, using a screw from one manufacturer with another's abutments should be approached with caution. Always consult the manufacturer's guidelines to ensure compatibility and proper function.

could dental implant cause oral lichen planus

FAQ

1. What is the standard hex driver size for BioHorizons abutments?

- The standard hex driver size for BioHorizons abutments is 0.050” (1.25 mm).

2. Can I use a Nobel 1.25 hex screw with BioHorizons abutments?

- Theoretically, yes, if the specific implant design allows for it, but always check with the manufacturer for compatibility.

3. What is the recommended torque for BioHorizons internal hex implants?

- The recommended torque for BioHorizons internal hex implants is 30 Ncm.

4. What are the risks of using incompatible abutment screws?

- Risks include improper fit, insufficient torque, and potential damage to the implant or abutment.

5. How do I ensure compatibility between different dental implant components?

- Always consult the manufacturer's guidelines and technical specifications to ensure compatibility.

Citations:

[1] http://blackburndentallab.com/wp-content/uploads/2023/08/AstraTech_Atlantis_Compatibility.pdf

[2] https://uniqa.dental/product/screw-for-abutment-for-biohorizons-internal-hex-tapered-internal-4-5-platform/

[3] https://www.biohorizons.com/Content/documents/eifu/L02028_Rev_D.pdf

[4] https://www.youtube.com/watch?v=eNHQhJ2AZis

[5] https://www.biohorizonscamlog.com/fileadmin/user_upload/03_Produkte/BioHorizons/Catalogs_and_documentations/TeethXPress_Manual_Small_L01021_Rev_G.pdf

[6] https://www.biohorizons.com/Content/Documents/eifu/L02008_Rev_K.pdf

[7] https://www.burdettedental.com/wp-content/uploads/2016/11/7204-Torque-Spec-Sheet.V5.web_.pdf

[8] https://www.youtube.com/watch?v=rJRxl504vgU

[9] https://it.biohorizons.com/Content/documents/eifu/L02020_Rev_D.pdf

[10] https://www.dentaltown.com/images/Dentaltown/magimages/0915/IDpg48.pdf

[11] https://store.nobelbiocare.com/se/en/rescue-drill-guide-external-hex-wp-1?___from_store=it_it&___store=se_en

[12] https://dpsdental.com/wp-content/uploads/2022/04/Implant-Torque-Guide-2022.pdf

[13] https://www.dessdental.com/en-eu/screw-hex-1-27-mm-compatible-with-biohorizons-internal

[14] https://www.biohorizons.com/Content/documents/eifu/L01024_Rev_B.pdf

[15] https://support.dess-usa.com/hc/en-us/articles/9895671367316-Understanding-Multiunit-Abutment-Tops

[16] https://biohorizonsperu.com/wp-content/uploads/L02024-Rev-H-Tapered-Family-Catalog-Manual.pdf

[17] https://www.astratechdental.es/Library/42657.pdf

[18] https://rosen-implant-solutions.com/product/x50-mua-rosen-screw-1-4mm/

[19] https://adldental.com/wp-content/uploads/2018/10/ADL_Torque-Spec-Sheet3.pdf

[20] https://ebook.biohorizonscamlog.com/bhcl/en/tapered-pro-catalog-and-manual/

[21] https://www.zestdent.com/locator-r-tx-biohorizons-tapered-pro-internal-hex-abutment

[22] https://www.youtube.com/c/Biohorizons1994/videos

[23] https://usstore.biohorizons.com/internalsingle-stage-abutment-screw

[24] https://www.biohorizons.com/Content/documents/eifu/L02024_Rev_B.pdf

[25] https://www.yumpu.com/en/document/view/50571518/multi-unit-abutments-biohorizons

[26] https://www.biohorizons.com/Content/documents/eifu/ML0115_Rev_F.pdf

[27] https://ebook.biohorizonscamlog.com/bhcl/en/teethxpress-manual/

[28] https://www.youtube.com/watch?v=f7zO0FgkqSM

CONTACT US

Shenzhen Yagu Dental Technology Co.,Ltd
  Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096
  Yagutech@hotmail.com
  8613631613096
 +8613631613096
Home
Copyright © Shenzhen Yagu Dental Technology Co.,Ltd
 Tianle Building,1021 Buji Road,Dongxiao Street,Luohu District,Shenzhen,Guangdong,China
  +8613631613096
  Yagutech@hotmail.com