Views: 222 Author: Dream Publish Time: 2025-04-19 Origin: Site
Content Menu
● Understanding the Implant System and Abutment Screw
● Why Does the Implant Crown Become Loose Due to Broken Abutment Screw?
>> Common Causes of Abutment Screw Fracture and Loosening
● Can You Reuse the Implant If the Abutment Screw Is Broken?
>> Factors Influencing Implant Reuse
● Techniques for Removing a Broken Abutment Screw
>> 1. Conservative Manual Removal
>> 2. Ultrasonic Instrumentation
>> 3. Modified Rotary Instruments and Burs
● When Is Implant Reuse Not Possible?
● Repairing and Replacing Components After Screw Removal
● Preventing Implant Crown Loosening Due to Broken Abutment Screws
>> Use of High-Quality Components
● What to Do If Your Implant Crown Becomes Loose Due to Broken Abutment Screw?
● Additional Considerations: Impact on Patient Experience and Costs
● Advanced Topics: Screw Fracture and Implant Design Innovations
● FAQ
>> 1. How common is it for an implant crown to become loose due to broken abutment screw?
>> 2. What are the risks of attempting to remove a broken abutment screw?
>> 3. Can the implant crown be reused after screw fracture?
>> 4. What should I do if my implant crown feels loose?
>> 5. Are there special tools needed to remove a broken abutment screw?
Dental implants have revolutionized tooth replacement, offering durable and natural-looking solutions. However, complications such as a broken abutment screw can cause the implant crown to become loose, posing challenges for both patients and clinicians. This article explores whether the implant can be reused if the abutment screw is broken, how to manage such situations, and the best practices for retrieval and repair.
A dental implant system typically consists of three main parts:
- Implant fixture: The titanium screw embedded into the jawbone.
- Abutment: The connector piece that attaches to the implant fixture.
- Crown: The visible tooth replacement attached to the abutment.
The abutment screw secures the abutment to the implant fixture. If this screw breaks, the implant crown becomes loose due to the compromised connection, affecting function and aesthetics.
The implant crown becomes loose due to broken abutment screw because the screw is the critical component holding the crown and abutment firmly to the implant. When the screw fractures, the stability of the entire prosthetic assembly is compromised, leading to mobility or loosening of the crown.
- Overloading the implant: Excessive biting forces, bruxism (teeth grinding), or trauma can fatigue the screw leading to fracture.
- Screw loosening: Micro-movements and improper torque application during placement can cause screw loosening, which predisposes to fracture.
- Poor fit or occlusal interference: Improper seating of the abutment or crown can create stress concentrations on the screw.
- Material fatigue or manufacturing defects: Inferior screw quality or design flaws contribute to failure.
Yes, in most cases, the implant fixture itself can be reused if the abutment screw breaks, provided the implant is undamaged and well-integrated with the bone. The broken screw fragment needs to be carefully removed to allow for replacement with a new screw and abutment.
- Condition of the implant: The implant must be free of damage, especially to the internal threads where the screw engages.
- Successful retrieval of the broken screw: If the broken screw fragment can be removed without damaging the implant, reuse is feasible.
- Absence of infection or bone loss: The implant site must be healthy with no peri-implantitis or bone resorption.
Removing a fractured abutment screw is challenging but essential to reuse the implant. Several techniques are used depending on the location and engagement of the broken screw fragment:
If the fractured piece is loose and accessible above the implant body, it can be grasped with hemostats or a sharp explorer and unscrewed counterclockwise.
Ultrasonic scalers can be applied to vibrate and loosen the screw fragment, especially if it is in the coronal third of the implant chamber.
- Creating a small slot or hole in the screw fragment with a diamond or tungsten carbide bur allows engagement with a screwdriver or reverse tap drill to back out the fragment.
- Customized burs or modified drills can be used to engage and rotate the broken screw out carefully.
Commercial kits designed specifically for implant screw removal provide drill guides, taps, and extraction tools to safely remove broken screws without damaging the implant threads.
- Converting a healing abutment to a prosthetic abutment if the screw fragment is irretrievable but the healing abutment height allows crown retention.
- Using adhesive dental restoration holders to engage and rotate the fragment.
- Internal thread damage: If screw removal attempts damage the implant's internal threads, the implant may become unusable.
- Irretrievable screw fragments: When the fragment is tightly embedded and cannot be removed despite all techniques.
- Implant failure or bone loss: If the implant is loose due to osseointegration failure, reuse is contraindicated.
In such cases, implant removal and replacement or alternative prosthetic solutions are considered.
Once the broken screw is removed, the following steps are taken:
- Inspect implant and abutment: Check for damage or wear.
- Insert new abutment screw: A new screw is placed and torqued to manufacturer specifications to avoid future loosening.
- Re-seat or replace the crown: The crown is reattached or replaced if damaged.
- Seal screw access: Composite resin or cement is used to seal the screw access hole on the crown.
Using a calibrated torque wrench to tighten the abutment screw to the manufacturer's recommended torque values is critical. Over-tightening can cause screw fatigue, while under-tightening leads to loosening.
Adjusting the bite to avoid excessive or off-axis forces reduces stress on the implant components. Patients with bruxism may benefit from night guards to protect the implant crown and abutment screw.
Routine dental check-ups allow early detection of screw loosening. Dentists can retighten screws or adjust the prosthesis before fracture occurs.
Selecting screws and abutments made from durable materials with improved design and surface treatments enhances resistance to fatigue and fracture.
If you notice your implant crown feels loose, do not attempt to remove or adjust it yourself. Contact your dental professional immediately for evaluation. Early intervention can prevent further damage to the implant or surrounding bone.
A broken abutment screw causing the implant crown to become loose can be distressing for patients. It may affect chewing function, speech, and aesthetics. The treatment to remove the broken screw and repair the implant can involve multiple visits and additional costs.
However, reusing the implant fixture when possible reduces the need for invasive surgery and lowers overall treatment expenses. Effective management and prevention strategies enhance patient satisfaction and long-term implant success.
Modern implant systems are continuously evolving to reduce complications like screw fracture. Innovations include:
- Improved screw materials: Use of titanium alloys with enhanced fatigue resistance.
- Enhanced screw designs: Screws with modified thread geometry to distribute stress more evenly.
- Platform switching: Using smaller diameter abutments on wider implant platforms to reduce stress concentration.
- Use of locking mechanisms: Some systems incorporate anti-rotation features or screwless abutments to minimize loosening.
These advancements contribute to lowering the incidence of implant crown becoming loose due to broken abutment screw.
Aspect | Details |
---|---|
Cause of looseness | Broken abutment screw compromises crown stability |
Implant reuse | Possible if implant undamaged and screw fragment removed |
Screw removal methods | Manual, ultrasonic, rotary instruments, retrieval kits |
When reuse not possible | Thread damage, irretrievable screw, implant failure |
Prevention | Proper torque, occlusal adjustment, maintenance, quality parts |
When an implant crown becomes loose due to broken abutment screw, the primary goal is to safely remove the fractured screw fragment without damaging the implant. In most cases, the implant fixture remains intact and can be reused after screw retrieval and replacement. Various conservative and advanced techniques exist to manage this challenging complication. Prompt diagnosis and treatment prevent further damage and restore implant function. Preventive measures including proper torque, occlusal management, and regular maintenance reduce the risk of screw loosening and fracture, ensuring the longevity of dental implants.
Abutment screw fracture is uncommon but significant, occurring in approximately 0.5–8% of cases, often due to screw loosening and overloading.
Risks include damaging the implant's internal threads, making the implant unusable, and prolonging treatment time.
Yes, if the implant and abutment are undamaged and the broken screw fragment is successfully removed, the crown can often be reseated or replaced as needed.
Contact your dentist promptly for evaluation. Early intervention can prevent screw fracture and implant damage.
Yes, screw retrieval kits, ultrasonic scalers, and modified burs are commonly used to safely remove fractured screws.
[1] https://pmc.ncbi.nlm.nih.gov/articles/PMC9369788/
[2] https://advanceddentistryinstitute.com.au/understanding-implant-crown-screw-loosening/
[3] https://www.journalofosseointegration.eu/jo/article/download/502/358
[4] https://avinent.com/pt-pt/blog/tornillos-fracturados-implantoprotesis/
[5] https://www.youtube.com/watch?v=IDh-a2Wr9fI
[6] https://www.dentistrytoday.com/a-simple-technique-for-broken-abutment-screw-repair/
[7] https://www.drbrettlangston.com/blog/removing-a-broken-dental-implant-screw/
[8] https://firstchoicelab.com/loose-abutment-screw-youre-not-alone/
[9] https://pubmed.ncbi.nlm.nih.gov/25865293/
[10] https://burbankdentalimplants.com/how-to-fix-a-broken-dental-implant-screw-a-case-report-burbank-dentist-ramsey-amin-dds-explains/
[11] https://pmc.ncbi.nlm.nih.gov/articles/PMC5644013/
[12] https://www.perioimplantadvisory.com/clinical-tips/article/16412202/fractured-dental-implant-screw-complications-3-methods-for-screw-retrieval
[13] https://stomadentlab.com/loose-implant-crowns-in-patients/
[14] https://journals.lww.com/jpcd/fulltext/2022/12030/retrieval_of_fractured_implant_abutment_screws__a.2.aspx
[15] https://www.adhp.com/managing-a-broken-implant-screw/
[16] https://dentalspecialtiesnw.com/symptoms-of-a-loose-dental-implant-crown/
[17] https://rockvilledentalarts.com/what-to-do-if-your-implant-crown-is-loose/
[18] https://www.mdpi.com/2076-3417/14/24/11846
[19] https://www.yagudentaltech.com/can-you-reuse-an-implant-with-a-broken-abutment-screw.html
[20] https://uniqa.dental/cases/what-to-do-if-the-screw-in-the-implant-breaks/
[21] https://johoe.kmu.ac.ir/article_92713.html
[22] https://www.perioimplantadvisory.com/clinical-tips/article/16412202/fractured-dental-implant-screw-complications-3-methods-for-screw-retrieval
[23] https://pubmed.ncbi.nlm.nih.gov/25706262/
[24] https://rockvilledentalarts.com/what-to-do-if-your-implant-crown-is-loose/
[25] https://www.thejcdp.com/doi/10.5005/jp-journals-10024-1435
[26] https://www.dentistrytoday.com/loose-screw-on-an-implant-crown-why-now-what-can-be-done/
[27] https://www.jaypeedigital.com/doi/IJCID/pdf/10.5005/jp-journals-10004-1035
[28] https://www.smiledesigndentistry.com/fix-loose-dental-implants/
[29] https://actascientific.com/ASDS/pdf/ASDS-08-1856.pdf
[30] https://www.shutterstock.com/search/implant-screw
[31] https://www.rcperio.com/implant-complications/
[32] https://www.shutterstock.com/search/dental-implant-abutment
[33] https://www.istockphoto.com/photos/abutment
[34] https://www.alamy.com/stock-photo/implant-screw.html
[35] https://www.mdpi.com/2079-4983/15/4/96
[36] https://www.youtube.com/watch?v=fKYEl3TauKE
[37] https://www.youtube.com/watch?v=f7zO0FgkqSM
[38] https://www.youtube.com/watch?v=tzjB933qkuI
[39] https://www.youtube.com/watch?v=bAtcvqeb53g
[40] https://www.youtube.com/watch?v=KRxhNszN-bs
[41] https://www.youtube.com/watch?v=2mf6B-GGMJI
[42] https://www.msdsmiles.com/blog/loose-implant-crown
[43] https://www.drtoddmanela.com/blog/605468-what-to-do-when-your-dental-implants-are-damaged
[44] https://pmc.ncbi.nlm.nih.gov/articles/PMC11050945/
[45] https://resnikimplantinstitute.com/blog/management-of-fractured-abutment-screws/
[46] https://hannadentalimplants.com/symptoms-of-loose-dental-implant-crown/
[47] https://compendiumlive.com/2021/04/abutment-screw-loosening-due-to-dental-laboratory-error
[48] https://www.southernimplants.com/pdf/Screw-Information/Broken_Screw_Removal_Protocol.pdf
[49] http://www.implantswiss.com/img/upl/catalog/ImplantswissRemovalHelpKit-0923-2.pdf
[50] https://www.perioimplantadvisory.com/dental-implants/article/14200668/my-dental-implant-screw-loosened-did-i-miss-something
[51] https://www.youtube.com/watch?v=BkfPZ1PUSCE
[52] https://www.youtube.com/watch?v=jCTMhXiEpJU
What Are The Common Complications From Stripped Abutment Screws?
What Is The Difference Between Titanium And Gold Straumann Abutment Screws?
Are Straumann Abutment Torque Values Different For Custom And Standard Abutments?
How Effective Is The Straumann Screw Removal Kit For Dental Implants?
Can Stainless Steel Abutment Screws Be Used In All Implant Systems?
How Do You Replace A Short Abutment Screw In Hiossen Implants?