Views: 222 Author: Dream Publish Time: 2025-04-15 Origin: Site
Content Menu
● Understanding Hiossen Multi Unit Abutment Screws
>> What Are Hiossen Multi Unit Abutment Screws?
>> Key Features of Hiossen Multi Unit Abutment Screws
● Compatibility of Hiossen Multi Unit Screws with Other Implant Systems
>> Cross-Brand Compatibility Overview
>> Specific Compatible Systems
>> Limitations and Risks of Using Non-Original Screws
● Detailed Analysis of Hiossen Multi Unit Abutment Screw Compatibility
● Practical Considerations for Clinicians
>> Selecting the Right Multi Unit Abutment Screw
>> Torque Application and Tools
>> Maintenance and Replacement
>> Clinical Tips for Cross-Compatibility Use
● Advances in Multi Unit Abutment Screw Technology
● FAQ
>> 1. Are Hiossen multi unit abutment screws interchangeable with Osstem implant systems?
>> 2. Can I use Hiossen multi unit screws with Nobel Biocare implants?
>> 3. What torque should be applied to Hiossen multi unit abutment screws?
>> 4. What materials are Hiossen multi unit abutment screws made from?
>> 5. What are the risks of using non-original screws with Hiossen implants?
Dental implantology has evolved significantly, with multi-unit abutments and screws playing a crucial role in prosthetic restorations. Among these, the Hiossen multi unit abutment screw is widely recognized for its precision and reliability. However, a common question among dental professionals is whether these screws are compatible with other implant systems. This comprehensive article explores the compatibility of Hiossen multi unit screws, their features, and practical considerations for clinicians.
Hiossen multi unit abutment screws are specialized components designed to secure multi-unit abutments to dental implants. These screws are typically made from high-grade titanium alloys (such as Ti-6AL-4V-ELI) to ensure strength, corrosion resistance, and biocompatibility. They are engineered to fit precisely with Hiossen implant platforms, particularly the Conical Connection ET™ System, which is known for its stability and ease of use.
The multi unit abutment screw is a critical element in implant-supported prosthetics, as it ensures the abutment remains firmly attached to the implant fixture, providing a stable foundation for crowns, bridges, or full-arch prostheses. The design of the Hiossen multi unit abutment screw incorporates features that minimize micro-movements and reduce the risk of screw loosening, a common complication in implant dentistry.
- Material: Medical-grade titanium (Grade 5 ELI) for durability and biocompatibility.
- Design: Precision-machined threads and anti-rotational features to prevent loosening.
- Torque Specifications: Recommended tightening torque is typically around 30 Ncm for optimal fixation.
- Compatibility: Designed primarily for Hiossen implant systems but with some cross-compatibility potential.
- Variety: Available in different lengths and angulations (straight, 17°, 30°) to accommodate various clinical scenarios.
The screw's design also includes a hexagonal or internal hex driver interface, allowing for secure engagement with the driver tool during placement and removal. This design reduces the risk of stripping the screw head, which can complicate retrieval.
Hiossen multi unit abutment screws are primarily designed for Hiossen implants, but due to the standardized dimensions and connection types in the implant industry, some degree of compatibility with other systems exists. For example, the Hiossen Conical Connection ET™ System shares similarities with Osstem implants, allowing certain components, including multi-unit abutment screws, to be interchangeable.
This cross-compatibility is particularly relevant in clinical situations where a practitioner may need to replace a screw or abutment but does not have access to the original manufacturer's components. Understanding which systems are compatible can save time and reduce costs.
- Osstem Implants: Hiossen screws and multi-unit abutments are often compatible with Osstem implant platforms, especially in the ET system line, due to shared connection designs. Both systems use a conical connection with similar platform diameters and thread pitches, which facilitates interchangeability.
- Nobel Biocare: Some Hiossen multi-unit abutments and screws, particularly the classic M1.4 fixation screw, are designed to work with Nobel Biocare's Active™ and Replace Select™ systems, offering cross-brand usability. However, this compatibility is limited and should be verified on a case-by-case basis.
- Other Systems: Compatibility with other implant brands depends on the implant connection type (internal hex, conical connection, etc.) and platform size. It is crucial to verify the exact specifications before mixing components. For example, Straumann and Zimmer Biomet implants have proprietary connections that may not be compatible with Hiossen screws.
- Fit and Stability: Using screws not specifically designed for a given implant system can lead to improper fit, resulting in micro-movements, screw loosening, or implant failure. Even slight differences in thread pitch or screw length can compromise the mechanical stability of the implant-abutment interface.
- Torque Mismatch: Different systems require specific torque values; using incompatible screws may cause over- or under-tightening. Over-tightening can strip threads or fracture the screw, while under-tightening increases the risk of loosening.
- Warranty and Liability: Manufacturers typically do not cover failures caused by mixing components from different brands. This can lead to legal and financial consequences if complications arise.
- Biocompatibility Concerns: Although most screws are made from titanium alloys, slight variations in alloy composition or surface treatment can affect corrosion resistance and biocompatibility.
Feature | Hiossen Multi Unit Screw | Osstem Implant System | Nobel Biocare System |
---|---|---|---|
Connection Type | Conical Connection ET™ System | Similar Conical Connection ET™ System | Internal Hex / Conical Connection |
Screw Material | Ti-6AL-4V-ELI Titanium | Titanium Alloy | Titanium Alloy |
Recommended Torque | 30 Ncm (varies by abutment type) | Similar torque values | 22-30 Ncm depending on abutment |
Cross-Compatibility | Compatible with Osstem; limited with Nobel Biocare | Compatible with Hiossen in ET system | Limited; specific screws required |
Anti-Rotational Features | Yes, with specific implant platform matching | Yes | Yes |
Platform Diameter Range | 3.5mm to 6.0mm | 3.5mm to 6.0mm | Varies, often proprietary |
This table summarizes the key factors influencing compatibility. The conical connection design used by Hiossen and Osstem is a major factor enabling interchangeability. However, even within similar connection types, slight dimensional differences can affect screw fit.
- Always verify the implant system and platform size before selecting a screw.
- Use manufacturer-recommended screws to ensure optimal fit and function.
- Consider the angulation of the abutment (straight, 17°, 30°) as screws may vary accordingly.
- Check the screw length to ensure it fully engages the implant threads without bottoming out or being too short.
- Use the correct driver (e.g., 1.2mm hex for Hiossen screws) and torque wrench.
- Follow the recommended torque values (usually 30 Ncm for Hiossen multi unit abutment screws) to avoid screw loosening or fracture.
- Apply torque gradually and in a controlled manner to prevent sudden over-tightening.
- Re-torque screws after initial placement if recommended by the manufacturer, typically after 10-15 minutes.
- Regularly check screw tightness during follow-up visits, especially in the first year after prosthesis placement.
- Replace screws if signs of wear, deformation, or loosening are detected.
- Use original or compatible replacement screws to maintain system integrity.
- Educate patients on avoiding excessive forces on implant-supported prostheses to reduce screw loosening risk.
- When using Hiossen multi unit abutment screws on other implant systems, perform a trial fit to check for proper engagement and torque resistance.
- Avoid mixing components in critical load-bearing areas unless compatibility is confirmed.
- Document any use of non-original components in patient records for medico-legal protection.
Recent innovations in multi unit abutment screws, including those by Hiossen, focus on improving mechanical stability and ease of use:
- Surface Treatments: Enhanced surface coatings reduce friction and improve screw preload retention.
- Anti-Loosening Designs: Incorporation of thread-locking features and optimized thread geometry.
- Digital Workflow Integration: Screws and abutments designed for compatibility with digital impression and CAD/CAM systems streamline prosthetic fabrication.
- Material Improvements: Use of titanium alloys with improved fatigue resistance extends screw longevity.
These advancements contribute to the overall success of implant-supported restorations and reduce complications related to screw loosening or fracture.
Hiossen multi unit abutment screws are precision-engineered components designed primarily for Hiossen implant systems, especially the Conical Connection ET™ System. Due to standardized implant connection designs, these screws exhibit a degree of compatibility with other implant systems such as Osstem and, to a limited extent, Nobel Biocare. However, clinicians must exercise caution when mixing components from different manufacturers to avoid complications related to fit, torque, and long-term stability. Using original or verified compatible screws ensures the best clinical outcomes and longevity of implant-supported prostheses.
By understanding the design features, compatibility considerations, and clinical best practices related to Hiossen multi unit abutment screws, dental professionals can make informed decisions that enhance patient care and implant success.
Yes, Hiossen multi unit abutment screws are generally compatible with Osstem implants, particularly within the ET system line, due to similar conical connection designs.
Some Hiossen screws, like the M1.4 fixation screw, are designed for cross-brand use with Nobel Biocare's Active™ and Replace Select™ systems, but it is recommended to use original screws for best fit and performance.
The recommended torque for tightening Hiossen multi unit abutment screws is typically 30 Ncm, but this may vary slightly depending on the abutment type and implant system.
They are made from medical-grade titanium alloy, specifically Ti-6AL-4V-ELI (Grade 5), which offers high strength and corrosion resistance.
Using non-original screws can lead to improper fit, screw loosening, implant instability, and may void manufacturer warranties. It is best to use original or verified compatible screws.
[1] https://shop.straumann.com/medentika/di/en_di/MPS/HiOssen-Implant--compatible/c/cat_med_hiossen
[2] https://www.ddsgadget.com/hiossen-compatible-multi-unit-straight-abutment.html
[3] https://hiossen.com/wp-content/uploads/2024/01/Hiossen-Implant-System_PC24HISLTR1.0.pdf
[4] https://www.ddsgadget.com/hiossen-compatible-multi-unit-17-degree-abutment.html
[5] https://uniqa.dental/compatibility/hiossen/
[6] https://www.preat.com/product/hiossen-hg-compatible-regular-straight-multi-unit-abutment-x-4-5mm
[7] https://edisonmed.com/17-angled-classic-multi-unit-abutment-m1-4-hiossenr-conical-conn-ettm-system-mini-np
[8] https://glidewelldirect.com/products/multi-unit-abutment-hiossen-hg-mini-025mmh
[9] https://shop.creomc.com/products/hiossen-multi-unit-coping-with-screw
[10] https://www.arumdentalshop.fr/pack-of-10-arum-multiunit-screw-m-r-compatible-with-osstemr
[11] https://hiossen.com/wp-content/uploads/2022/05/Product-Catalog_2022.pdf
[12] https://www.dess-usa.com/Osstem-compatible-screws/
[13] https://hiossen.com/products/stock-abutments/
[14] https://32dentalab.com/products/multi-abutment-final-screw-osstem%C2%AE-ts-hiossen%C2%AE-et-compatible
[15] https://uniqa.dental/product/straight-multi-unit-abutment-d-type-for-hiossen-conical-connection-et-system-rp/
[16] https://www.arumdentalshop.fr/pack-of-10-arum-multiunit-screw-m-r-compatible-with-osstemr
[17] https://www.osstem.com.hk/wp-content/uploads/2021/08/Hiossen-Catalog_2021-edited-23-Apr-2021-e-version.pdf
[18] https://eshop.hiossen.com/prosthetics/et-system/multi-abutment/
[19] https://shop.creomc.com/products/hiossen-multi-unit-coping-with-screw
[20] https://glidewelldirect.com/products/multi-unit-abutment-angled-screw-hiossen-hg-standard
[21] https://eshop.hiossen.com/multi-ti-base/
[22] https://eshop.hiossen.com
[23] https://shop.straumann.com/medentika/nz/en_nz/MPS/HiOssen-Implant--compatible/c/cat_med_hiossen
[24] https://shop.straumann.com/medentika/se/en_se/MPS/HiOssen-Implant--compatible/c/cat_med_hiossen
[25] https://shop.straumann.com/medentika/us/en_us/MPS/HiOssen-Implant--compatible/c/cat_med_hiossen
[26] https://ticrom.com/screw/screw-multiunit/
[27] https://www.youtube.com/watch?v=yPG8Abn20uo
[28] https://www.youtube.com/watch?v=uyfu4JMl-X4
[29] https://www.dess-usa.com/straight-multiunit-abutment-3-5mm-collar-height-mini-40-072-3/
[30] https://dentallabnetwork.com/forums/threads/screw-coming-loose-repeatedly-whats-wrong.31924/
[31] https://www.preat.com/product/hiossen-hg-compatible-regular-straight-multi-unit-abutment-x-1-5mm
[32] https://shop.creomc.com/products/hiossen-multi-unit-temporary-cylinder
[33] https://www.hiossenimplantcanada.ca/osseointegrated-implant-complications-management/
[34] https://www.dess-usa.com/Osstem-multiunit-abutments/
[35] https://uniqa.dental/product/50-x-mua-rosen-screw-1-4mm-compatible-with-hiossen-multi-units/
[36] https://uniqa.dental/cases/what-to-do-if-the-screw-in-the-implant-breaks/
[37] https://hiossen.com/wp-content/uploads/2022/05/Denture-4U-Multi-Ti-Base_Letter_202107_PB21D4BA4R1.0_Email.pdf
[38] https://www.arumdentalshop.com/arum-multiunit-scanbody-m-r-compatible-with-osstemr-includes-screw
[39] https://www.youtube.com/watch?v=rJRxl504vgU
[40] https://www.youtube.com/watch?v=hqy45AUzcA8
[41] https://pmc.ncbi.nlm.nih.gov/articles/PMC7222622/
[42] https://cmukdental.co.uk/shop/dess/component/mua-multi-unit-abutments/osstem-ts-hiossen-et-mua-multi-unit-abutments/dess-conic-oss-osstem-ts-hiossen-et-mua-multi-unit-abutment/
[43] https://paragon-implant.com/latest-controversies/shortcomings-of-hiossens-implants/
What Are The Common Complications From Stripped Abutment Screws?
What Is The Difference Between Titanium And Gold Straumann Abutment Screws?
Are Straumann Abutment Torque Values Different For Custom And Standard Abutments?
How Effective Is The Straumann Screw Removal Kit For Dental Implants?
Can Stainless Steel Abutment Screws Be Used In All Implant Systems?
How Do You Replace A Short Abutment Screw In Hiossen Implants?